{"title":"Air to Water Heat Pumps, Hydronic Fan Coil Units, Control, etc...","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThe Air to Water Pump is a revolution in heat pump technology that remains unsurpassed in terms of cost and performance. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eDesigned with a mission to make it the most efficient cold climate heat pump on the market at a price point of ½ of a traditional geothermal heat pump. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThis was done without any sacrifices to quality. Industry leading parts were mandated in the design of this unit.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"evi-dc-inverter-split-type-air-to-water-heat-pump-model-hss030v2ls-operating-temperatures-25-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Split, DC Inverter, R410a","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e25⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V2LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-25⁰C (-13⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 14.8 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 20.78\/ 37.2 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 7.7 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R410a Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypcial ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heatig temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage evrything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture5.png?v=1718211045\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to swtich between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"TABLE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/03063.png?v=1675388404\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CF30S.png?v=1718214303\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LS_REV15.pdf?v=1717441963\" title=\"Manual_English\"\u003e\u003cimg alt=\"manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LS_F_REV4.pdf?v=1717515805\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"manuel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":36609105395873,"sku":"17010230","price":7820.92,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v2ls-operating-temperatures-25-c-to-45-c-37527717576950.png?v=1659665394"},{"product_id":"braced-single-bracket-30-inches-long","title":"Braced Single Bracket - 30 Inches Long","description":"\u003c!-- more --\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\" alt=\"dimensions\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599070970017,"sku":"B494-30-1","price":265.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/braced-single-bracket-30-inches-long-28564119879841.jpg?v=1617990018"},{"product_id":"braced-double-bracket-30-inches-long","title":"Braced Double Bracket - 30 Inches Long","description":"\u003c!-- more --\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\" alt=\"dimensions\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599106850977,"sku":"B494-30-2","price":420.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/braced-double-bracket-30-inches-long-28548076273825.jpg?v=1617821057"},{"product_id":"copy-of-braced-double-bracket-30-inches-long","title":"Two Channels Bracket - 30 Inches Long","description":"\u003cimg alt=\"double channel bracket\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/t4.jpg?v=1617819850\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599133098145,"sku":"B297-30-1","price":215.05,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/two-channels-bracket-30-inches-long-28548125130913.jpg?v=1617821024"},{"product_id":"two-channels-double-bracket-30-inches-long","title":"Two Channels Double Wall Bracket - 30 Inches Long","description":"\u003cimg alt=\"double channel bracket\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/t4.jpg?v=1617819850\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599152070817,"sku":"B297-30-2","price":420.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/two-channels-double-bracket-30-inches-long-28548164878497.jpg?v=1617820993"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-5-tons-monoblock-model-hss060v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-copy","title":"Air to Water Heat Pump, 5 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS060V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 5 Tons (60 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 55 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 29.67 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 48.16 \/ 65.84 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 13.0 (Water) \/ 15.47 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 10.7.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypcial ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/060.jpg?v=1763063362\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CF60M.png?v=1718207841\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":46787725394166,"sku":"160104060","price":9563.17,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-5-ton-monoblock-dc-inverter-r32-1242731876.png?v=1780611250"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-20-tons-monobloc-model-hss250v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 20 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS250V3LM (Copper Heat Exchanger) - HSS250V3LM-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 20 Tons (250 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 380-415V \/ 3 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 67 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 72 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 115 \/ 207 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 79.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 3\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cspan\u003e\u003cstrong\u003eCSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e, \u003cstrong\u003eCAN\/CSA-C22.2 NO. 60335-1:16 (R2021)\u003c\/strong\u003e, \u003cstrong\u003eUL 60335-2-40:2022\u003c\/strong\u003e and \u003cstrong\u003eUL 60335-1:2016\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/250.jpg?v=1763067228\"\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool_real.png?v=1724782539\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_French\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833895768310,"sku":"160104250","price":38056.73,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833895801078,"sku":"1601032501","price":42024.65,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224870367478,"sku":"160105250","price":41878.48,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-20-tons-monobloc-model-hss250v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808230486262.png?v=1718845972"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-40-tons-monobloc-model-hss500v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 40 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS500V3LM (Copper Heat Exchanger) - HSS500V3LM-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 40 Tons (480 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: \u003cstrong\u003e380-415V \/ 3 Ph \/ 60Hz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 69 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 114 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 230 \/ 414 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 158.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 4\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cspan\u003e\u003cstrong\u003eCSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e, \u003cstrong\u003eCAN\/CSA-C22.2 NO. 60335-1:16 (R2021)\u003c\/strong\u003e, \u003cstrong\u003eUL 60335-2-40:2022\u003c\/strong\u003e and \u003cstrong\u003eUL 60335-1:2016\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/500.jpg?v=1763067228\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool.png?v=1724782043\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833916117238,"sku":"160104500","price":60298.12,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833916150006,"sku":"1601035001","price":76144.26,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224871153910,"sku":"160105500","price":69261.75,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-40-tons-monobloc-model-hss500v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808241135862.png?v=1718846689"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-20-tons-split-model-hss250v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 20 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS250V3LS (Copper Heat Exchanger) - HSS250V3LS-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 20 Tons (250 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 380-415V \/ 3 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 67 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 72 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 115 \/ 207 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 79.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 3\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" title=\"Certification\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eUL 1995:2015 R8.18 \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/250.jpg?v=1763067228\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool_real.png?v=1724782539\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_rev1.pdf?v=1751905320\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_French\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833942790390,"sku":"170104250","price":42923.64,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833942823158,"sku":"1701032501","price":42923.64,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224854049014,"sku":"170105250","price":44873.22,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-20-tons-split-model-hss250v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808313258230.png?v=1718847408"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-40-tons-split-model-hss500v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 40 Ton Split, DC Inverter, R32","description":"\u003cp\u003e \u003c\/p\u003e\n\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS500V3LS (Copper Heat Exchanger) - HSS500V3LS-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 40 Tons (480 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: \u003cstrong\u003e380-415V \/ 3 Ph \/ 60Hz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 69 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 114 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 230 \/ 414 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 158.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 4\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/500.jpg?v=1763067228\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool.png?v=1724782043\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV8.pdf?v=1786045246\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833950884086,"sku":"170103500","price":69645.31,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833950916854,"sku":"1701035001","price":67503.74,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224853098742,"sku":"170105500","price":74039.58,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-40-tons-split-model-hss500v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808349630710.png?v=1718847948"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-7-tons-split-model-hss080v3ls-r32a-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 7 Ton Split, DC Inverter, R32","description":"\u003cp\u003e\u003c!-- more --\u003e\u003c\/p\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS080V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 7 Tons (80 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 58 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 33.2 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 53.53 \/ 96.36 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 19.2 (Water).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1 1\/4\" (DN32).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t.png?v=1718886418\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t.png?v=1718886433\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/080.jpg?v=1763063362\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_7-ton_-_1.png?v=1729708163\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"manuel\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" title=\"METHOD STATEMENT\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\" alt=\"dx LINES\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" title=\"METHOD STATEMENT\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e \u003c\/h2\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47376807067894,"sku":"170104080","price":14656.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-7-ton-split-dc-inverter-r32-1242731874.png?v=1780611188"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v3ls-r32a-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-13⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 14.8 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 20.78 \/ 37.2 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 8.2 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/030.jpg?v=1763063234\" alt=\"\"\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_2-ton_-1.png?v=1729709289\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg alt=\"manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"manuel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"manuel_Francais\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV5.pdf?v=1763063548\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47377006756086,"sku":"170104030","price":8535.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-1242731875.png?v=1780611131"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-5-tons-split-model-hss060v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 5 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS060V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 5 Tons (60 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 55 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 25.34 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 44.46\/ 60.75 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 13 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 10.7.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/060.jpg?v=1763063362\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_5-ton_-1.png?v=1729710020\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"manuel\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47377036542198,"sku":"170104060","price":12162.16,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-7-ton-split-dc-inverter-r32-1242731874.png?v=1780611188"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-2-tons-monobloc-model-hss030v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 16.23 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 29.41 \/ 39.56 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 8.2 (Water) \/ 9.7 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/030.jpg?v=1763063234\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_2-ton_m.png?v=1729863165\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003ca title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV2.pdf?v=1674155894\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47384189731062,"sku":"160104030","price":6406.3,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-2-5-ton-monoblock-dc-inverter-r32-1242731877.png?v=1780611069"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-7-tons-monoblock-model-hss080v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 7 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between\u003cstrong\u003e -30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS080V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 7 Tons (80 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 58 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 38.05 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 58.72 \/ 100.78 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 19.2 (Water) \/ 22 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1 1\/4\" (DN32).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=1\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/080.jpg?v=1763063362\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_7-ton_m.png?v=1729863733\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e \u003cspan\u003e \u003c\/span\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e \u003c\/h2\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47384220532982,"sku":"160104080","price":11579.66,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-5-ton-monoblock-dc-inverter-r32-1242731876.png?v=1780611250"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-2-tons-monobloc-model-hsp025-r32-refrigerant-operating-temperatures-15-c-to-45-c-copy","title":"Air to Water Pool Heat Pump - EVI DC Inverter 2 tons - Model HSP025 - R32 Refrigerant - Operating Temperatures -15⁰C To +45⁰C","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePool Series Air-to-Water Heat Pump\u003c\/strong\u003e is a thermal device that extracts heat energy from the ambient air (heat source) and transfers it directly to pool water (heat sink) via the R32 refrigerant cycle. The Pool heat pump can also cool your pool water when necessary. Unlike closed-loop systems, where heat is transferred to a recirculating fluid mixture (like water\/glycol), our pool heat pumps deliver heat directly to the pool water in an open-loop configuration. This allows efficient and continuous heating and cooling of the pool without the need for an intermediate heat exchanger. The \u003cstrong\u003ePool Series\u003c\/strong\u003e operates reliably in outdoor temperatures ranging from \u003cstrong\u003e-15⁰C\u003c\/strong\u003e to \u003cstrong\u003e+45⁰C\u003c\/strong\u003e, ensuring energy-efficient pool heating and cooling even in challenging climates.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSP025.\u003c\/li\u003e\n\u003cli\u003eNominal Heating Capacity: 2 Tons (25,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-15⁰C (5⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 48 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 9.2 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 11.7 \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 0.33.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1-1\/2\" FNPT.\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eChilled Water Supply Temperature: Nominal 28⁰C (82.4⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eHot Water Supply Temperature: Nominal 29.7⁰C (85.5⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol.\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016, UL 60335-2-40:2022, CAN\/CSA-C22.2 NO. 60335-1:16 (R2021) \u003c\/strong\u003eand\u003cstrong\u003e CSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW Pool HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe below configuration is that recommended for the optimal performance of the pool and spa heat pump:\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/English_Pool_HP_Schematic.png?v=1770998881\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eThe controller of the Heat Pump is designed to manage the water pumping between the HP and the pool. This includes the pool water circulation pump and the backup heat.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Untitled_design_6_a25409aa-34ab-4314-9d25-54937a702c6d.png?v=1767972993\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING AND COOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP025_Performance_3f3d82d5-10b2-4478-97f8-1d553408e6f9.png?v=1767964795\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV1.pdf?v=1768401551\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_Logo.png?v=1761245084\" alt=\"\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV4.pdf?v=1759945486\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":49222078529782,"sku":"340101025","price":3366.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-pool-heat-pump-evi-dc-inverter-2-tons-model-hsp025-r32-refrigerant-operating-temperatures-15-c-to-45-c-1199109429.png?v=1761149550"},{"product_id":"air-to-water-pool-heat-pump-evi-dc-inverter-4-tons-model-hsp050-r32-refrigerant-operating-temperatures-15-c-to-45-c","title":"Air to Water Pool Heat Pump - EVI DC Inverter 4 tons - Model HSP050 - R32 Refrigerant - Operating Temperatures -15⁰C To +45⁰C","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePool Series Air-to-Water Heat Pump\u003c\/strong\u003e is a thermal device that extracts heat energy from the ambient air (heat source) and transfers it directly to pool water (heat sink) via the R32 refrigerant cycle. The Pool heat pump can also cool your pool water when necessary. Unlike closed-loop systems, where heat is transferred to a recirculating fluid mixture (like water\/glycol), our pool heat pumps deliver heat directly to the pool water in an open-loop configuration. This allows efficient and continuous heating and cooling of the pool without the need for an intermediate heat exchanger. The \u003cstrong\u003ePool Series\u003c\/strong\u003e operates reliably in outdoor temperatures ranging from \u003cstrong\u003e-15⁰C\u003c\/strong\u003e to \u003cstrong\u003e+45⁰C\u003c\/strong\u003e, ensuring energy-efficient pool heating and cooling even in challenging climates.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSP050.\u003c\/li\u003e\n\u003cli\u003eNominal Heating Capacity: 4 Tons (50,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-15⁰C (5⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 16.9 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 19.35. \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 1.00.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1-1\/2\" FNPT.\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eChilled Water Supply Temperature: Nominal 28⁰C (82.4⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eHot Water Supply Temperature: Nominal 29.7⁰C (85.5⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol.\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016, UL 60335-2-40:2022, CAN\/CSA-C22.2 NO. 60335-1:16 (R2021) \u003c\/strong\u003eand\u003cstrong\u003e CSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW Pool HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe below configuration is that recommended for the optimal performance of the pool and spa heat pump:\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/English_Pool_HP_Schematic.png?v=1770998881\"\u003e\u003c\/div\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eThe controller of the Heat Pump is designed to manage the water pumping between the HP and the pool. This includes the pool water circulation pump and the backup heat.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Untitled_design_6_a25409aa-34ab-4314-9d25-54937a702c6d.png?v=1767972993\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING AND COOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP050_Performance_d65faaae-57e1-44a1-a52c-c55cb4f2181f.png?v=1767964795\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV1.pdf?v=1768401551\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_Logo.png?v=1761245084\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manuel\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV4.pdf?v=1759945486\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":49225341599990,"sku":"340101050","price":4029.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-pool-heat-pump-evi-dc-inverter-2-tons-model-hsp025-r32-refrigerant-operating-temperatures-15-c-to-45-c-1199109429.png?v=1761149550"},{"product_id":"air-to-water-pool-heat-pump-evi-dc-inverter-5-tons-model-hsp060-r32-refrigerant-operating-temperatures-15-c-to-45-c","title":"Air to Water Pool Heat Pump - EVI DC Inverter 5 tons - Model HSP060 - R32 Refrigerant - Operating Temperatures -15⁰C To +45⁰C","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePool Series Air-to-Water Heat Pump\u003c\/strong\u003e is a thermal device that extracts heat energy from the ambient air (heat source) and transfers it directly to pool water (heat sink) via the R32 refrigerant cycle. The Pool heat pump can also cool your pool water when necessary. Unlike closed-loop systems, where heat is transferred to a recirculating fluid mixture (like water\/glycol), our pool heat pumps deliver heat directly to the pool water in an open-loop configuration. This allows efficient and continuous heating and cooling of the pool without the need for an intermediate heat exchanger. The \u003cstrong\u003ePool Series\u003c\/strong\u003e operates reliably in outdoor temperatures ranging from \u003cstrong\u003e-15⁰C\u003c\/strong\u003e to \u003cstrong\u003e+45⁰C\u003c\/strong\u003e, ensuring energy-efficient pool heating and cooling even in challenging climates.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSP060.\u003c\/li\u003e\n\u003cli\u003eNominal Heating Capacity: 5 Tons (60,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-15⁰C (5⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 54 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 21.7 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 27.45. \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 2.34.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1-1\/2\" FNPT.\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eChilled Water Supply Temperature: Nominal 28⁰C (82.4⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eHot Water Supply Temperature: Nominal 29.7⁰C (85.5⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol.\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016, UL 60335-2-40:2022, CAN\/CSA-C22.2 NO. 60335-1:16 (R2021) \u003c\/strong\u003eand\u003cstrong\u003e CSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW Pool HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe below configuration is that recommended for the optimal performance of the pool and spa heat pump:\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/English_Pool_HP_Schematic.png?v=1770998881\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eThe controller of the Heat Pump is designed to manage the water pumping between the HP and the pool. This includes the pool water circulation pump and the backup heat.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Untitled_design_6_a25409aa-34ab-4314-9d25-54937a702c6d.png?v=1767972993\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING AND COOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP060_Performance_4ffc3b84-37ef-4b30-8cef-60758b10b9fc.png?v=1767964795\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV1.pdf?v=1768401551\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_Logo.png?v=1761245084\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manuel\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV4.pdf?v=1759945486\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":49225461137654,"sku":"340101060","price":5508.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-pool-heat-pump-evi-dc-inverter-2-tons-model-hsp025-r32-refrigerant-operating-temperatures-15-c-to-45-c-1199109429.png?v=1761149550"},{"product_id":"air-to-water-pool-heat-pump-evi-dc-inverter-8-tons-model-hsp095-r32-refrigerant-operating-temperatures-15-c-to-45-c","title":"Air to Water Pool Heat Pump - EVI DC Inverter 8 tons - Model HSP095 - R32 Refrigerant - Operating Temperatures -15⁰C To +45⁰C","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePool Series Air-to-Water Heat Pump\u003c\/strong\u003e is a thermal device that extracts heat energy from the ambient air (heat source) and transfers it directly to pool water (heat sink) via the R32 refrigerant cycle. The Pool heat pump can also cool your pool water when necessary. Unlike closed-loop systems, where heat is transferred to a recirculating fluid mixture (like water\/glycol), our pool heat pumps deliver heat directly to the pool water in an open-loop configuration. This allows efficient and continuous heating and cooling of the pool without the need for an intermediate heat exchanger. The \u003cstrong\u003ePool Series\u003c\/strong\u003e operates reliably in outdoor temperatures ranging from \u003cstrong\u003e-15⁰C\u003c\/strong\u003e to \u003cstrong\u003e+45⁰C\u003c\/strong\u003e, ensuring energy-efficient pool heating and cooling even in challenging climates.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSP095.\u003c\/li\u003e\n\u003cli\u003eNominal Heating Capacity: 8 Tons (95,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-15⁰C (5⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 54 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 31.9 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 43.2. \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 6.69.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1-1\/2\" FNPT.\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eChilled Water Supply Temperature: Nominal 28⁰C (82.4⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eHot Water Supply Temperature: Nominal 29.7⁰C (85.5⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol.\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016, UL 60335-2-40:2022, CAN\/CSA-C22.2 NO. 60335-1:16 (R2021) \u003c\/strong\u003eand\u003cstrong\u003e CSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW Pool HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe below configuration is that recommended for the optimal performance of the pool and spa heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/English_Pool_HP_Schematic.png?v=1770998881\"\u003e\u003c\/div\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eThe controller of the Heat Pump is designed to manage the water pumping between the HP and the pool. This includes the pool water circulation pump and the backup heat.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Untitled_design_6_a25409aa-34ab-4314-9d25-54937a702c6d.png?v=1767972993\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING AND COOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP095_Performance_10d28979-6176-4627-a159-c8b881ee5d84.png?v=1767964795\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV1.pdf?v=1768401551\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_Logo.png?v=1761245084\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV0.pdf?v=1761138140\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manuel\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV4.pdf?v=1759945486\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":49225513271542,"sku":"340101095","price":7242.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-pool-heat-pump-evi-dc-inverter-2-tons-model-hsp025-r32-refrigerant-operating-temperatures-15-c-to-45-c-1199109429.png?v=1761149550"},{"product_id":"air-to-water-pool-heat-pump-evi-dc-inverter-10-tons-model-hsp120-r32-refrigerant-operating-temperatures-15-c-to-45-c","title":"Air to Water Pool Heat Pump - EVI DC Inverter 10 tons - Model HSP120 - R32 Refrigerant - Operating Temperatures -15⁰C To +45⁰C","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePool Series Air-to-Water Heat Pump\u003c\/strong\u003e is a thermal device that extracts heat energy from the ambient air (heat source) and transfers it directly to pool water (heat sink) via the R32 refrigerant cycle. The Pool heat pump can also cool your pool water when necessary. Unlike closed-loop systems, where heat is transferred to a recirculating fluid mixture (like water\/glycol), our pool heat pumps deliver heat directly to the pool water in an open-loop configuration. This allows efficient and continuous heating and cooling of the pool without the need for an intermediate heat exchanger. The \u003cstrong\u003ePool Series\u003c\/strong\u003e operates reliably in outdoor temperatures ranging from \u003cstrong\u003e-15⁰C\u003c\/strong\u003e to \u003cstrong\u003e+45⁰C\u003c\/strong\u003e, ensuring energy-efficient pool heating and cooling even in challenging climates.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSP120.\u003c\/li\u003e\n\u003cli\u003eNominal Heating Capacity: 10 Tons (120,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-15⁰C (5⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 58 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 38.6 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 53.55. \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 8.36.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1-1\/2\" FNPT.\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eChilled Water Supply Temperature: Nominal 28⁰C (82.4⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli style=\"font-style: italic;\"\u003e\u003cem\u003eHot Water Supply Temperature: Nominal 29.7⁰C (85.5⁰F).\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol.\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016, UL 60335-2-40:2022, CAN\/CSA-C22.2 NO. 60335-1:16 (R2021) \u003c\/strong\u003eand\u003cstrong\u003e CSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW Pool HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe below configuration is that recommended for the optimal performance of the pool and spa heat pump:\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/English_Pool_HP_Schematic.png?v=1770998881\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eThe controller of the Heat Pump is designed to manage the water pumping between the HP and the pool. This includes the pool water circulation pump and the backup heat.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Untitled_design_6_a25409aa-34ab-4314-9d25-54937a702c6d.png?v=1767972993\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING AND COOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP120_Performance_6bba4aca-8389-44c3-859c-a79ebffa940d.png?v=1767964795\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSP0250506095120_REV1.pdf?v=1768401551\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_Logo.png?v=1761245084\" alt=\"\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV4.pdf?v=1759945486\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":49225676652790,"sku":"340101120","price":9078.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-pool-heat-pump-evi-dc-inverter-10-tons-model-hsp120-r32-refrigerant-operating-temperatures-15-c-to-45-c-1199109439.png?v=1761156753"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/air-to-water-heat-pumps-hydronic-fan-coil-units-control-etc.jpg?v=1618933476","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/air-to-water-heat-pumps.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}