{"title":"Air Handling Unit - CWA2,  2 Pipe Vertical Ducted - 1.5 to 5 Tons Capacities","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eDucted Hydronic Air Handling Unit, 2 pipe system with only one coil for either heating or cooling. AHU has one Horizontal and one Vertical drain pans, which makes it suitable for horizontal and vertical installations.\u003c\/p\u003e","products":[{"product_id":"air-handling-unit-24cwa200-2-pipe-vertical-ducted-2-tons-capacity","title":"Air Handling Unit - 24CWA200,  2 Pipe Vertical Ducted - 2 Tons Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003eEquipment:\u003c\/h4\u003e\n\u003cp\u003eFactory assembled and tested multi-position chilled\/ hot water with electric heat\u003cbr\u003efan coil with factory wiring, piping, associated controls and special\u003cbr\u003eaccessories required prior to start up.\u003c\/p\u003e\n\u003ch4\u003eUnit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanised steel casing with baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eInternally insulated for a quiet operation.\u003c\/li\u003e\n\u003cli\u003eCabinet can be installed in a vertical or horizontal position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in 208\/230-1-60 VAC.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBlower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWater Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminium fins.\u003c\/li\u003e\n\u003cli\u003eCoils is be factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoil contains manual air bleed port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDrain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDrain pan is molded with high impact polymers.\u003c\/li\u003e\n\u003cli\u003ePan contains a primary and secondary drain connection.\u003c\/li\u003e\n\u003cli\u003ePan is capable of draining in the vertical and horizontal positions without changing the pan configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFilters:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit shall contain a filter door for easy access to the filter.\u003c\/li\u003e\n\u003cli\u003eA filter track shall be provided.\u003c\/li\u003e\n\u003cli\u003eUnit shall come supplied with a 1” throwaway filter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectric Heaters with Circuit Breaker:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is capable of incorporating an electric heat package.\u003c\/li\u003e\n\u003cli\u003eElectric heaters are of the open wire type.\u003c\/li\u003e\n\u003cli\u003eElectric heat packages contain non-fused breakers, sequencers and safeties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested (not included with the Fan Coil)..\u003c\/li\u003e\n\u003cli\u003eUnit includes a terminal block that is capable of incorporating a 24 VAC thermostat.\u003c\/li\u003e\n\u003cli\u003eEach Fan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003eElectric heat package contains non-fusible breakers and high temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CWA2_nomenclature.jpg?v=1646933892\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/24CWA2_Submittal_Rev1.3.pdf\" target=\"_blank\" title=\"Technical Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/CWA2_IOM_Rev1.2.pdf\" title=\"O \u0026amp; M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca title=\"wiring\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/24CWA2_Wiring_Diagram__Certifed_Drawing.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":42698326147318,"sku":"490724200","price":4933.61,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/air-handling-unit-24cwa200-2-pipe-vertical-ducted-2-tons-capacity-36759079747830.png?v=1646934892"},{"product_id":"air-handling-unit-36cwa200-2-pipe-vertical-ducted-3-tons-capacity","title":"Air Handling Unit - 36CWA200,  2 Pipe Vertical Ducted - 3 Tons Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003eEquipment:\u003c\/h4\u003e\n\u003cp\u003eFactory assembled and tested multi-position chilled\/ hot water with electric heat\u003cbr\u003efan coil with factory wiring, piping, associated controls and special\u003cbr\u003eaccessories required prior to start up.\u003c\/p\u003e\n\u003ch4\u003eUnit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanised steel casing with baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eInternally insulated for a quiet operation.\u003c\/li\u003e\n\u003cli\u003eCabinet can be installed in a vertical or horizontal position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in 208\/230-1-60 VAC.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBlower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWater Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminium fins.\u003c\/li\u003e\n\u003cli\u003eCoils is be factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoil contains manual air bleed port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDrain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDrain pan is molded with high impact polymers.\u003c\/li\u003e\n\u003cli\u003ePan contains a primary and secondary drain connection.\u003c\/li\u003e\n\u003cli\u003ePan is capable of draining in the vertical and horizontal positions without changing the pan configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFilters:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit shall contain a filter door for easy access to the filter.\u003c\/li\u003e\n\u003cli\u003eA filter track shall be provided.\u003c\/li\u003e\n\u003cli\u003eUnit shall come supplied with a 1” throwaway filter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectric Heaters with Circuit Breaker:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is capable of incorporating an electric heat package.\u003c\/li\u003e\n\u003cli\u003eElectric heaters are of the open wire type.\u003c\/li\u003e\n\u003cli\u003eElectric heat packages contain non-fused breakers, sequencers and safeties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested (not included with the Fan Coil)..\u003c\/li\u003e\n\u003cli\u003eUnit includes a terminal block that is capable of incorporating a 24 VAC thermostat.\u003c\/li\u003e\n\u003cli\u003eEach Fan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003eElectric heat package contains non-fusible breakers and high temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CWA2_nomenclature.jpg?v=1646933892\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/36CWA2_Submittal_Rev1.3.pdf\" target=\"_blank\" title=\"Technical Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/CWA2_IOM_Rev1.2.pdf\" title=\"O \u0026amp; M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/36CWA2_Wiring_Diagram__Certifed_Drawing.pdf\" target=\"_blank\" title=\"wiring\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":42698349052150,"sku":"490736200","price":4164.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/air-handling-unit-36cwa200-2-pipe-vertical-ducted-3-tons-capacity-36759085744374.png?v=1646935072"},{"product_id":"air-handling-unit-48cwa200-2-pipe-vertical-ducted-4-tons-capacity","title":"Air Handling Unit - 48CWA200,  2 Pipe Vertical Ducted - 4 Tons Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003eEquipment:\u003c\/h4\u003e\n\u003cp\u003eFactory assembled and tested multi-position chilled\/ hot water with electric heat\u003cbr\u003efan coil with factory wiring, piping, associated controls and special\u003cbr\u003eaccessories required prior to start up.\u003c\/p\u003e\n\u003ch4\u003eUnit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanised steel casing with baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eInternally insulated for a quiet operation.\u003c\/li\u003e\n\u003cli\u003eCabinet can be installed in a vertical or horizontal position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in 208\/230-1-60 VAC.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBlower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWater Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminium fins.\u003c\/li\u003e\n\u003cli\u003eCoils is be factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoil contains manual air bleed port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDrain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDrain pan is molded with high impact polymers.\u003c\/li\u003e\n\u003cli\u003ePan contains a primary and secondary drain connection.\u003c\/li\u003e\n\u003cli\u003ePan is capable of draining in the vertical and horizontal positions without changing the pan configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFilters:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit shall contain a filter door for easy access to the filter.\u003c\/li\u003e\n\u003cli\u003eA filter track shall be provided.\u003c\/li\u003e\n\u003cli\u003eUnit shall come supplied with a 1” throwaway filter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectric Heaters with Circuit Breaker:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is capable of incorporating an electric heat package.\u003c\/li\u003e\n\u003cli\u003eElectric heaters are of the open wire type.\u003c\/li\u003e\n\u003cli\u003eElectric heat packages contain non-fused breakers, sequencers and safeties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested (not included with the Fan Coil)..\u003c\/li\u003e\n\u003cli\u003eUnit includes a terminal block that is capable of incorporating a 24 VAC thermostat.\u003c\/li\u003e\n\u003cli\u003eEach Fan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003eElectric heat package contains non-fusible breakers and high temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CWA2_nomenclature.jpg?v=1646933892\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/48CWA2_Submittal_Rev1.3.pdf\" target=\"_blank\" title=\"Technical Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/CWA2_IOM_Rev1.2.pdf\" title=\"O \u0026amp; M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/48CWA2_Wiring_Diagram__Certifed_Drawing.pdf\" target=\"_blank\" title=\"wiring\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":42698372153590,"sku":"490748200","price":4925.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/air-handling-unit-48cwa200-2-pipe-vertical-ducted-4-tons-capacity-36759098786038.png?v=1646935254"},{"product_id":"copy-of-air-handling-unit-48cwa200-2-pipe-vertical-ducted-4-tons-capacity","title":"Air Handling Unit - 60CWA200,  2 Pipe Vertical Ducted - 5 Tons Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003eEquipment:\u003c\/h4\u003e\n\u003cp\u003eFactory assembled and tested multi-position chilled\/ hot water with electric heat\u003cbr\u003efan coil with factory wiring, piping, associated controls and special\u003cbr\u003eaccessories required prior to start up.\u003c\/p\u003e\n\u003ch4\u003eUnit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanised steel casing with baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eInternally insulated for a quiet operation.\u003c\/li\u003e\n\u003cli\u003eCabinet can be installed in a vertical or horizontal position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in 208\/230-1-60 VAC.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBlower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWater Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminium fins.\u003c\/li\u003e\n\u003cli\u003eCoils is be factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoil contains manual air bleed port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDrain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDrain pan is molded with high impact polymers.\u003c\/li\u003e\n\u003cli\u003ePan contains a primary and secondary drain connection.\u003c\/li\u003e\n\u003cli\u003ePan is capable of draining in the vertical and horizontal positions without changing the pan configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFilters:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit shall contain a filter door for easy access to the filter.\u003c\/li\u003e\n\u003cli\u003eA filter track shall be provided.\u003c\/li\u003e\n\u003cli\u003eUnit shall come supplied with a 1” throwaway filter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectric Heaters with Circuit Breaker:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is capable of incorporating an electric heat package.\u003c\/li\u003e\n\u003cli\u003eElectric heaters are of the open wire type.\u003c\/li\u003e\n\u003cli\u003eElectric heat packages contain non-fused breakers, sequencers and safeties.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested (not included with the Fan Coil)..\u003c\/li\u003e\n\u003cli\u003eUnit includes a terminal block that is capable of incorporating a 24 VAC thermostat.\u003c\/li\u003e\n\u003cli\u003eEach Fan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003eElectric heat package contains non-fusible breakers and high temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CWA2_nomenclature.jpg?v=1646933892\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/60CWA2_Submittal_Rev1.3.pdf\" target=\"_blank\" title=\"Technical Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/CWA2_IOM_Rev1.2.pdf\" title=\"O \u0026amp; M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/60CWA2_Wiring_Diagram__Certifed_Drawing.pdf\" target=\"_blank\" title=\"wiring\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":42698393288950,"sku":"490760200","price":5919.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/copy-of-air-handling-unit-60cwa200-2-pipe-vertical-ducted-5-tons-capacity-36759105994998.png?v=1646935433"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/Multiaqua-CWA2_1.png?v=1646797113","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/cwa2-chilled-water-2-pipe-air-handler-1-5-to-5-tons-capacities.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}