{"title":"Fan Coil Unit-MCFCW 4-Pipe Chilled\/Hot Water, Ceiling Concealed Cased - 208\/230V, 1 to 5 Tons","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eMultiaqua Chilled Water Fan Coils are manufactured with heavy gauge galvanized steel to resist corrosion.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCertified in accordance with U.L. Standard 95, latest version (U.S.A.)\u003c\/li\u003e\n\u003cli\u003eManufactured in a facility registered to ISO 9002, Manufacturing Quality Standard.\u003c\/li\u003e\n\u003cli\u003eFully load tested at the factory. D. Damage resistant packaging.\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-1ph-50-60hz-1-to-5-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V-1Ph-50\/60Hz, 1 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-04-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-04-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-04_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"1 Ton \/ Low Static","offer_id":42742593945846,"sku":"480607044","price":4241.91,"currency_code":"CAD","in_stock":true},{"title":"1 Ton \/ High Static","offer_id":42742593978614,"sku":"4808090441","price":4319.55,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-1ph-50-60hz-1-to-5-ton-capacity-36775780221174.png?v=1647308573"},{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-1-5-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 1.5 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-06-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-06-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-06_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"1.5 Ton \/ Low Static","offer_id":42742644998390,"sku":"480607064","price":4500.57,"currency_code":"CAD","in_stock":true},{"title":"1.5 Ton \/ High Static","offer_id":42742645031158,"sku":"4808090641","price":4570.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-1-5-ton-capacity-36775786414326.png?v=1647308934"},{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-2-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 2 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-08-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-08-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-08_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"2 Ton \/ Low Static","offer_id":42742657319158,"sku":"480607084","price":5293.08,"currency_code":"CAD","in_stock":true},{"title":"2 Ton \/ High Static","offer_id":42742657351926,"sku":"4808090841","price":5390.91,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-2-ton-capacity-36775797227766.png?v=1647309114"},{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-3-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 3 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"3 Ton \/ Low Static","offer_id":42742665478390,"sku":"480607124","price":6266.5,"currency_code":"CAD","in_stock":true},{"title":"3 Ton \/ High Static","offer_id":42742665511158,"sku":"4808091241","price":6536.48,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-3-ton-capacity-36775803420918.png?v=1647309472"},{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-4-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 4 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-16-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-16-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-16_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"4 Ton \/ Low Static","offer_id":42742671507702,"sku":"480607164","price":7142.53,"currency_code":"CAD","in_stock":true},{"title":"4 Ton \/ High Static","offer_id":42742671540470,"sku":"4808091641","price":7475.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-4-ton-capacity-36775810433270.png?v=1647309653"},{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-5-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 5 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-20-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-20-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-20_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"5 Ton \/ Low Static","offer_id":42742676422902,"sku":"480607204","price":8081.01,"currency_code":"CAD","in_stock":true},{"title":"5 Ton \/ High Static","offer_id":42742676455670,"sku":"4808092041","price":9203.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-5-ton-capacity-36775815446774.png?v=1647309833"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/MCFCW.png?v=1647306579","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/fan-coil-unit-mcfcw-4-pipe-chilled-hot-water-ceiling-concealed-cased-208-230v-1-to-5-tons.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}