{"title":"Fan Coil Unit - MHCCW Chilled or Hot Water Ceiling Concealed, 2-Pipe, 220V, 1 to 3 Tons Capacity","description":"\u003cspan data-mce-fragment=\"1\"\u003eCeiling Concealed 2 Pipes Fan Coil units, 230V, Hydronic Heating and Cooling, capacities 1 to 3 tons.\u003c\/span\u003e","products":[{"product_id":"fan-coil-enclosure","title":"Fan Coil Unit Enclosure (MPE468)","description":"\u003c!-- more --\u003e\n\u003ch1\u003eFAN COIL ENCLOSURE\u003c\/h1\u003e\n\u003cp\u003eThe fan coil enclosure assembly has a supply air duct flange to allow the attachment of ductwork. Ensure when attaching ductwork to the flange, that the screws are at least one and half inches away from the front of the enclosure. This is to allow proper insertion of the fan coil assembly into the enclosure assembly.\u003c\/p\u003e\n\u003cp\u003eWhen mounting the service access panel, louvered or non-louvered, the installing contractor must provide a frame in order to connect the enclosure assembly to the service access panel. This is required to obtain an airtight seal for the return air. Ensure that the material used for the frame adheres to national codes and \/ or local codes and regulations. Care must be taken when installing the service access panel to ensure the opening of the hinged service panel.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/AS.png?v=1589999145\" alt=\"DIMENSIONS\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"MPE468 for MHCCW-2 PIPE-1 to 2 Tons","offer_id":42755992191222,"sku":"470405468","price":722.43,"currency_code":"CAD","in_stock":true},{"title":"MPE10 for MHCCW-2 PIPE-2.5 Tons","offer_id":42755992223990,"sku":"MPE10","price":748.0,"currency_code":"CAD","in_stock":true},{"title":"MPE12 for MHCCW-2 PIPE-3 Tons","offer_id":42755992256758,"sku":"MPE12","price":770.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-enclosure-mpe468-36782260584694.png?v=1647395399"},{"product_id":"fan-coil-unit-mhccw-04-00-1-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-04-00, 1 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-04-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca title=\"wiring\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-04-00_Wiring_Diagram__Dimensional_Drawing_Rev._1.1.pdf\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42709963636982,"sku":"47052300400","price":2925.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-04-00-1-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763684995318.png?v=1647030294"},{"product_id":"fan-coil-unit-mhccw-06-00-1-5-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-06-00, 1.5 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-06-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-06-00_Wiring_Diagram__Dimensional_Drawing_Rev._1.1.pdf\" title=\"wiring\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42709979824374,"sku":"47052300600","price":2925.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-06-00-1-5-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763699806454.png?v=1647030652"},{"product_id":"fan-coil-unit-mhccw-08-00-2-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-08-00, 2 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-08-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-08-00_Wiring_Diagram__Dimensional_Drawing_Rev.1.1.pdf\" title=\"wiring\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42710060630262,"sku":"47052300800","price":3094.34,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-08-00-2-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763709145334.png?v=1647031016"},{"product_id":"fan-coil-unit-mhccw-10-00-2-5-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-10-00, 2.5 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-10-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-10-00_Wiring_Diagram__Dimensional_Drawing_Rev._1.1.pdf\" title=\"wiring\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42710069608694,"sku":"470523010000","price":3569.65,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-10-00-2-5-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763718648054.png?v=1647031014"},{"product_id":"fan-coil-unit-mhccw-12-00-3-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-12-00, 3 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-12-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-12-00_Wiring_Diagram__Dimensional_Drawing_Rev._1.1.pdf\" title=\"wiring\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42710083404022,"sku":"47052301200","price":3822.77,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-12-00-3-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763730804982.png?v=1647031373"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/Untitled_design_17_bb16b3c3-1cdc-446c-8bbe-0c20cafbb3a3.png?v=1647030085","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/fan-coil-unit-mhccw-chilled-or-hot-water-ceiling-concealed-2-pipe-1-to3-tons-capacity.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}