{"title":"Air to Water Heat Pump - HYDRO SOLAR Brand","description":"\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeating and cooling shouldn't be complicated—or expensive. Our air to water heat pumps are built for real-world performance, offering a smarter, more efficient way to heat and cool your home or business.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOur air to water heat pump options offer energy-efficient solutions for heating and cooling. They transfer heat energy between outdoor and indoor spaces. \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/pages\/air-water-heat-pumps\"\u003e\u003cspan\u003eAir to water heat pumps\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e don’t just heat or cool the air like traditional air to air heat pumps, they use heat to regulate the temperature of water or a water-glycol mixture. That means radiant in-floor heating, low-temperature radiators, and domestic hot water production—all in one system. You get energy savings, precise temperature control, and quiet operation without the inefficiencies of older heating systems.\u003c\/span\u003e\u003c\/p\u003e\n","products":[{"product_id":"evi-dc-inverter-split-type-air-to-water-heat-pump-model-hss030v2ls-operating-temperatures-25-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Split, DC Inverter, R410a","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e25⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V2LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-25⁰C (-13⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 14.8 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 20.78\/ 37.2 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 7.7 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R410a Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypcial ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heatig temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage evrything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture5.png?v=1718211045\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to swtich between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"TABLE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/03063.png?v=1675388404\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CF30S.png?v=1718214303\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LS_REV15.pdf?v=1717441963\" title=\"Manual_English\"\u003e\u003cimg alt=\"manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LS_F_REV4.pdf?v=1717515805\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"manuel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":36609105395873,"sku":"17010230","price":7820.92,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v2ls-operating-temperatures-25-c-to-45-c-37527717576950.png?v=1659665394"},{"product_id":"braced-single-bracket-30-inches-long","title":"Braced Single Bracket - 30 Inches Long","description":"\u003c!-- more --\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\" alt=\"dimensions\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599070970017,"sku":"B494-30-1","price":265.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/braced-single-bracket-30-inches-long-28564119879841.jpg?v=1617990018"},{"product_id":"braced-double-bracket-30-inches-long","title":"Braced Double Bracket - 30 Inches Long","description":"\u003c!-- more --\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\" alt=\"dimensions\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/q4.jpg?v=1617819067\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599106850977,"sku":"B494-30-2","price":420.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/braced-double-bracket-30-inches-long-28548076273825.jpg?v=1617821057"},{"product_id":"copy-of-braced-double-bracket-30-inches-long","title":"Two Channels Bracket - 30 Inches Long","description":"\u003cimg alt=\"double channel bracket\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/t4.jpg?v=1617819850\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599133098145,"sku":"B297-30-1","price":215.05,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/two-channels-bracket-30-inches-long-28548125130913.jpg?v=1617821024"},{"product_id":"two-channels-double-bracket-30-inches-long","title":"Two Channels Double Wall Bracket - 30 Inches Long","description":"\u003cimg alt=\"double channel bracket\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/t4.jpg?v=1617819850\"\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":39599152070817,"sku":"B297-30-2","price":420.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/two-channels-double-bracket-30-inches-long-28548164878497.jpg?v=1617820993"},{"product_id":"grundfos-upmxl-25-124-230v-power-with-pwm-modulation-signal","title":"Grundfos UPMXL 25-124, 230V\/1Ph\/60Hz, Power with PWM Modulation Signal","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eUPML and UPMXL pumps for the North American market are UL and cUL approved. The type key is designed for the precise identification of the product and not for configuration purposes. It can be found on the product packaging. This Pump Model Number is \u003cstrong\u003eUPMXL 25-124 165F PWM 180W US 230V GFD.\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePump Range\/Type: UPM XL\u003c\/li\u003e\n\u003cli\u003eNominal Inlet and Outlet Diameter: DN25\u003c\/li\u003e\n\u003cli\u003eMaximum Head (Dm): 124\u003c\/li\u003e\n\u003cli\u003ePort to Port Length: 165 mm (4.19\")\u003c\/li\u003e\n\u003cli\u003eCast Iron Housing with 2-blot flanges\u003c\/li\u003e\n\u003cli\u003eExternal Control Signal: PWM (if absent Pump runs at full speed)\u003c\/li\u003e\n\u003cli\u003eNominal Power Consumption: 180 Watts\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V\/1Ph\/60Hz\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003ePerfromance Curve:\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/curve_4c5fc17a-08c5-42d9-ba82-923b46827f48.png?v=1718036980\"\u003e\u003c\/p\u003e\n\u003ch2\u003eInstallation Position:\u003c\/h2\u003e\n\u003cp\u003eThe pump must always be installed with horizontal motor shaft within ± 5 °. The pump should be installed in the system in such a way that no major amount of air flowing through the pump or gathering in the pump housing will affect the pump when it is out of operation. If, in addition, a check valve is installed in the flow pipe, there is a high risk of dry running as the air cannot pass the valve.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe pump is designed to be installed pumping upwards or downwards.\u003c\/li\u003e\n\u003cli\u003eArrows on the pump housing indicate the liquid flow direction through the pump.\u003c\/li\u003e\n\u003cli\u003eif the pump is installed horizontally, the conduit box must point downwards. Be aware that the pump connection, flange or union nut, might interfere with the control box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_ba086495-0caf-4674-8975-b1bc54c7088b.png?v=1718037344\"\u003e\u003c\/p\u003e\n\u003cp\u003eWhen making pipe connections, follow the piping manufacturer's recommendations\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the check valve, if required.\u003c\/li\u003e\n\u003cli\u003eRefer to the arrows on the pump housing that indicate the direction of the liquid flow through the pump.\u003c\/li\u003e\n\u003cli\u003eInstall the pump with horizontal motor shaft.\u003c\/li\u003e\n\u003cli\u003eFit gaskets to the pump ends.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePWM Signal \u0026amp; Wiring:\u003c\/h2\u003e\n\u003cp\u003eGRUNDFOS UPML and UPMXL PWM circulators are controlled via a digital low-voltage pulse-width modulation (PWM) signal which means that the speed of rotation depends on the input signal. The speed changes as a function of the input profile. These communication signals are standardized in the VDMA Einheitsblatt 24224 “Wet runner circulating pumps - Specification of PWM control signals”.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eDigital low-voltage PWM signal\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe square-wave PWM signal is designed for a 100 to 4000 Hz frequency range. The PWM signal is used to select the speed (speed command) and as feedback signal. The PWM frequency of the feedback signal is fixed at 75 Hz in the pump.\u003cbr\u003eDuty cycle: d % = 100 x t\/T\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_7987c905-2f54-4b53-bbf6-fba7c032277b.png?v=1718037547\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_c5c17140-d737-4a20-b2dd-6c0affb7cd64.png?v=1718037547\" alt=\"\"\u003ePWM Wiring\u003c\/h3\u003e\n\u003cp\u003eThe UPML\/UPMXL PWM pumps are externally speed-controlled by a digital low-voltage PWM signal. To enable pump control, a signal cable is required.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePWM A profile for Heating: Without signal the pump will always run at maximum speed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe signal cable has two or three leads. The signal cable must be connected to the control box by a dubox housing with an FCI terminal block and terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/4_820fa6fb-3f68-4e03-b60e-57d3a27ad8d2.png?v=1718037713\"\u003e\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cp\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/download_be8f8513-b8c8-4c29-ad6a-2057fe54432a.png?v=1738246546\"\u003e\u003cspan lang=\"EN-US\" style=\"font-size: 11.0pt; font-family: 'Aptos',sans-serif; mso-fareast-font-family: Calibri; mso-fareast-theme-font: minor-latin; mso-bidi-font-family: Aptos; mso-ansi-language: EN-US; mso-fareast-language: FR-CA; mso-bidi-language: AR-SA;\"\u003e\u003c!--[endif]--\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/UPMXL_-_USA_115V.pdf?v=1718038077\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_3_5f00fe2b-1d51-4aee-9efa-74cd3dbbe9cf.png?v=1714067278\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!----\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":46780502245622,"sku":"","price":789.71,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/grundfos-upmxl-25-124-230v-power-with-pwm-modulation-signal-40755894124790.png?v=1718036509"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-5-tons-monoblock-model-hss060v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-copy","title":"Air to Water Heat Pump, 5 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS060V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 5 Tons (60 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 55 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 29.67 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 48.16 \/ 65.84 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 13.0 (Water) \/ 15.47 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 10.7.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypcial ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/060.jpg?v=1763063362\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/CF60M.png?v=1718207841\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":46787725394166,"sku":"160104060","price":9563.17,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-5-ton-monoblock-dc-inverter-r32-1242731876.png?v=1780611250"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-20-tons-monobloc-model-hss250v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 20 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS250V3LM (Copper Heat Exchanger) - HSS250V3LM-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 20 Tons (250 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 380-415V \/ 3 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 67 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 72 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 115 \/ 207 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 79.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 3\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cspan\u003e\u003cstrong\u003eCSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e, \u003cstrong\u003eCAN\/CSA-C22.2 NO. 60335-1:16 (R2021)\u003c\/strong\u003e, \u003cstrong\u003eUL 60335-2-40:2022\u003c\/strong\u003e and \u003cstrong\u003eUL 60335-1:2016\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/250.jpg?v=1763067228\"\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool_real.png?v=1724782539\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_French\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833895768310,"sku":"160104250","price":38056.73,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833895801078,"sku":"1601032501","price":42024.65,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224870367478,"sku":"160105250","price":41878.48,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-20-tons-monobloc-model-hss250v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808230486262.png?v=1718845972"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-40-tons-monobloc-model-hss500v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 40 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS500V3LM (Copper Heat Exchanger) - HSS500V3LM-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 40 Tons (480 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: \u003cstrong\u003e380-415V \/ 3 Ph \/ 60Hz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 69 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 114 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 230 \/ 414 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 158.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 4\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cspan\u003e\u003cstrong\u003eCSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e, \u003cstrong\u003eCAN\/CSA-C22.2 NO. 60335-1:16 (R2021)\u003c\/strong\u003e, \u003cstrong\u003eUL 60335-2-40:2022\u003c\/strong\u003e and \u003cstrong\u003eUL 60335-1:2016\u003c\/strong\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/500.jpg?v=1763067228\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool.png?v=1724782043\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg alt=\"Manual_English\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Manual_English\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833916117238,"sku":"160104500","price":60298.12,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833916150006,"sku":"1601035001","price":76144.26,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224871153910,"sku":"160105500","price":69261.75,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-40-tons-monobloc-model-hss500v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808241135862.png?v=1718846689"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-20-tons-split-model-hss250v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 20 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS250V3LS (Copper Heat Exchanger) - HSS250V3LS-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 20 Tons (250 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 380-415V \/ 3 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 67 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 72 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 115 \/ 207 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 79.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 3\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72407285?locale=en\" title=\"Certification\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003eUL 1995:2015 R8.18 \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/250.jpg?v=1763067228\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool_real.png?v=1724782539\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_rev1.pdf?v=1751905320\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"Manual_French\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833942790390,"sku":"170104250","price":42923.64,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833942823158,"sku":"1701032501","price":42923.64,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224854049014,"sku":"170105250","price":44873.22,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-20-tons-split-model-hss250v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808313258230.png?v=1718847408"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-40-tons-split-model-hss500v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 40 Ton Split, DC Inverter, R32","description":"\u003cp\u003e \u003c\/p\u003e\n\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between -\u003cstrong\u003e30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS500V3LS (Copper Heat Exchanger) - HSS500V3LS-T (Titanium Heat Exchanger).\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 40 Tons (480 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-20.2⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: \u003cstrong\u003e380-415V \/ 3 Ph \/ 60Hz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 69 dBA.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 114 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 230 \/ 414 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 158.\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 4\" Flanged.\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250500.jpg?v=1768234572\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It also has the possibility to be managed by a third party controller: it can be turned ON\/OFF via port 8-9, and switched between heating (ON) and cooling (OFF) via port 10-11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/500.jpg?v=1763067228\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/hss250_cool.png?v=1724782043\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV9.pdf?v=1787845545\" target=\"_blank\" title=\"Manual_English\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_TEMPORARY_REV8.pdf?v=1786045246\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS250-500V3LM-S_DATA_SHEET_FRENCH_TEMPORARY_REV8.pdf?v=1787845527\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Standard","offer_id":46833950884086,"sku":"170103500","price":69645.31,"currency_code":"CAD","in_stock":true},{"title":"Titanium for Swimming Pools","offer_id":46833950916854,"sku":"1701035001","price":67503.74,"currency_code":"CAD","in_stock":false},{"title":"Double Wall Heat Exchanger","offer_id":48224853098742,"sku":"170105500","price":74039.58,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-40-tons-split-model-hss500v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-40808349630710.png?v=1718847948"},{"product_id":"grundfos-pump-magna3-65-150f-208-230v-cast-iron-variable-speed-pump-98126852","title":"Grundfos Pump MAGNA3 65-150F - 208-230V Cast Iron Variable Speed Pump (98126852)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch1 style=\"display: inline !important;\" class=\"page_headers\" data-mce-style=\"display: inline !important;\" itemprop=\"name\"\u003e\u003cspan style=\"color: #000000;\" data-mce-style=\"color: #000000;\"\u003eGrundfos MAGNA3 65-150F - 208-230V Cast Iron Variable Speed Pump\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eThe MAGNA3 is a circulator pump based on the tried and tested MAGNA technology and our industry-leading experience with electronic pumps. The permanent magnet motor, AUTOadapt function and integrated frequency converter is still part of the MAGNA package, but we’ve added some additional, ground-breaking new technologies. The result is a cutting-edge piece of intelligent technology that retains the unrivalled Grundfos reliability.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cdiv style=\"font-size: 0.875rem;\" class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\" data-mce-style=\"font-size: 0.875rem;\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/magna_curve.png?v=1727367952\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"General Information\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Grundfosliterature-4609551.pdf?v=1727368237\" target=\"_blank\"\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_22.png?v=1709062435\" alt=\"General Information\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_22.png?v=1709062435\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\"\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\" style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" title=\"brochure\" rel=\"noopener\" style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":47286899835126,"sku":"99490914","price":5083.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/grundfos-pump-magna3-65-150f-208-230v-cast-iron-variable-speed-pump-98126852-41746214387958.png?v=1727471572"},{"product_id":"grundfos-pump-magna1-32-100-gf-165-115-230v-cast-iron-variable-speed-circulator-98126823","title":"Grundfos Pump MAGNA1 32-100 GF 165 115-230V Cast Iron Variable Speed Circulator (98126823)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch1 class=\"page_headers\" style=\"display: inline !important;\" itemprop=\"name\" data-mce-style=\"display: inline !important;\"\u003e\u003cspan style=\"color: #000000;\" data-mce-style=\"color: #000000;\"\u003eGrundfos MAGNA1 32-100 GF 165 115-230V Cast Iron Variable Speed Circulator\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eThe Grundfos MAGNA1 is a circulator pump with permanent magnet motor and easy selection of pump setting. The MAGNA1 will fit both heating, cooling and domestic hot water circulation applications perfectly, making it the obvious choice for almost any building project – old or new.\u003c\/p\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eThe pump is a canned-rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing.\u003c\/p\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eThe bearings are lubricated by the pumped liquid. A pump with no maintenance requirements and extremely low life cycle cost.\u003c\/p\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003eThe pump has an intuitive user interface, which is especially fit for replacement of older circulators. The ideal choice for basic performance needs in applications where system communication is not required.\u003c\/p\u003e\n\u003cp style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e \u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\" style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/magna1_curve.png?v=1727369330\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"General Information\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Grundfosliterature-5992758.pdf?v=1727369782\" target=\"_blank\"\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003cimg alt=\"General Information\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_22.png?v=1709062435\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_22.png?v=1709062435\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" title=\"brochure\" rel=\"noopener\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" target=\"_blank\"\u003e\u003cspan style=\"font-size: 0.875rem;\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"font-size: 0.875rem;\" class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\" data-mce-style=\"font-size: 0.875rem;\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cdiv class=\"b-layout-grid__group cmp-variant-product-data-row cmp-variant-product-data__table-row\"\u003e\n\u003cdiv class=\"b-layout-grid__item b-layout-grid__item--6\"\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003ca style=\"font-size: 0.875rem;\" rel=\"noopener\" title=\"brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Brochure.pdf?v=1709055436\" data-mce-style=\"font-size: 0.875rem;\"\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"Default Title","offer_id":47287024255222,"sku":"99490914","price":1826.4,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/grundfos-pump-magna1-32-100-gf-165-115-230v-cast-iron-variable-speed-circulator-98126823-41725288906998.jpg?v=1727471570"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-10-tons-split-model-hss120v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 10 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003ePerformance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS120V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 10 Tons (120 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 63 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 62.5 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 96 \/ 130 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 28 (Water).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 13.382.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 2\" (DN50).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equiped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eController uses Modbus Protocol (Table points is available upon).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72407445?locale=en\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUL 1995:2015 R8.18.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypcial ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t-50.png?v=1718886641\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS120.jpg?v=1768234576\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHeating Performance\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Performance_HSS120.jpg?v=1776177062\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCooling Performance\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/cooling_p.png?v=1730814577\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS120V3LS_REV10.pdf?v=1790962884\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS120V3LS_FRENCH_REV3.pdf?v=1792153274\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"manuel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47310135165174,"sku":"170104120","price":19366.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-10-ton-split-dc-inverter-r32-1254105440.png?v=1786644669"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-7-tons-split-model-hss080v3ls-r32a-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 7 Ton Split, DC Inverter, R32","description":"\u003cp\u003e\u003c!-- more --\u003e\u003c\/p\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS080V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 7 Tons (80 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 58 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 33.2 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 53.53 \/ 96.36 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 19.2 (Water).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1 1\/4\" (DN32).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2t.png?v=1718886418\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1t.png?v=1718886433\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/080.jpg?v=1763063362\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_7-ton_-_1.png?v=1729708163\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"manuel\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" title=\"METHOD STATEMENT\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\" alt=\"dx LINES\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" title=\"METHOD STATEMENT\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e \u003c\/h2\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47376807067894,"sku":"170104080","price":14656.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-7-ton-split-dc-inverter-r32-1242731874.png?v=1780611188"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v3ls-r32a-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-13⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 14.8 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 20.78 \/ 37.2 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 8.2 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Nominal 7⁰C (44.6⁰F), Minimum 5⁰C (41⁰F). Maximum 12⁰C (53.6⁰F).\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35⁰C (95⁰F), Maximum 60⁰C (140⁰F).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/030.jpg?v=1763063234\" alt=\"\"\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003cimg\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_2-ton_-1.png?v=1729709289\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg alt=\"manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg alt=\"manuel\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"manuel_Francais\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV5.pdf?v=1763063548\" target=\"_blank\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47377006756086,"sku":"170104030","price":8535.75,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-evi-dc-inverter-2-tons-split-model-hss030v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c-1242731875.png?v=1780611131"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-5-tons-split-model-hss060v3ls-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 5 Ton Split, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Split Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS060V3LS.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 5 Tons (60 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 55 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 25.34 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 44.46\/ 60.75 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 13 (Water) \u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 10.7.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72225518?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture6.png?v=1718214156\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture7.png?v=1718214172\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves (Floating type for 2 tanks configuration - 2 Pipe System and ON\/OFF type for single tank configuration or 2 tanks configuration with a 4 pipe system), Circulation Pump, DHW heating backup heat, Space heating Backup Heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/060.jpg?v=1763063362\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_5-ton_-1.png?v=1729710020\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_REV5.pdf?v=1784128690\" title=\"Manual_English\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"manual\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LS_F_REV6.pdf?v=1784128697\" title=\"manuel_Francais\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"manuel\"\u003e\u003c\/a\u003e \u003ca title=\"METHOD STATEMENT\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/METHOD_STATEMENT_REV0.pdf?v=1631842187\" target=\"_blank\"\u003e\u003cimg alt=\"dx LINES\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Refrigerant_Lines_Commissioning-240.png?v=1631842278\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47377036542198,"sku":"170104060","price":12162.16,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-7-ton-split-dc-inverter-r32-1242731874.png?v=1780611188"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-2-tons-monobloc-model-hss030v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 2.5 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between \u003cstrong\u003e-30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS030V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 2.5 Tons (30 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 52 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 16.23 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 29.41 \/ 39.56 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 8.2 (Water) \/ 9.7 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 9.03.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1\" (DN25).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" title=\"Titanium Heat Exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/030.jpg?v=1763063234\"\u003e\u003c\/p\u003e\n\u003ch2\u003eCOOLING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_2-ton_m.png?v=1729863165\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" title=\"FIRMWARE\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\" alt=\"FIRMWARE\"\u003e\u003c\/a\u003e\u003ca title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV2.pdf?v=1674155894\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V2LM_REV6.pdf?v=1710180206\" title=\"Manual_English\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47384189731062,"sku":"160104030","price":6406.3,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-2-5-ton-monoblock-dc-inverter-r32-1242731877.png?v=1780611069"},{"product_id":"air-to-water-heat-pump-evi-dc-inverter-7-tons-monoblock-model-hss080v3lm-r32-refrigerant-operating-temperatures-30-c-to-45-c","title":"Air to Water Heat Pump, 7 Ton Monoblock, DC Inverter, R32","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eHeating\/Cooling Performance\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eINTRODUCTION\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and rejects the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool\/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool\/heat water or water\/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoutdoor temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eranging between\u003cstrong\u003e -30⁰C and +45⁰C.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel Number: HSS080V3LM.\u003c\/li\u003e\n\u003cli\u003eNominal Cooling Capacity: 7 Tons (80 000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003eOutdoor Operating Temperature range: \u003cstrong\u003e-30⁰C (-22⁰F) to +45⁰C (113⁰F)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply: 220-240V \/ 1 Ph \/ 60Hz.\u003c\/li\u003e\n\u003cli\u003eNoise Level: 58 dBa.\u003c\/li\u003e\n\u003cli\u003eFull Load Amp (FLA): 38.05 A.\u003c\/li\u003e\n\u003cli\u003eMCA \/ MOP: 58.72 \/ 100.78 A.\u003c\/li\u003e\n\u003cli\u003eNominal Heat Transfer Fluid Flow (US GPM): 19.2 (Water) \/ 22 (50% Propylene Glycol).\u003c\/li\u003e\n\u003cli\u003eWater Friction Loss at Nominal Flow (ft W.G.): 12.71.\u003c\/li\u003e\n\u003cli\u003eWater Inlet\/Outlet Diameter: 1 1\/4\" (DN32).\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature: Minimum 7\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (44.6\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF). Maximum \u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e30°C (86°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature: Minimum 35\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (95\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF), Maximum 60\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eC (140\u003cspan class=\"a_GcMg font-feature-liga-off font-feature-clig-off font-feature-calt-off text-decoration-none text-strikethrough-none\"\u003e°\u003c\/span\u003eF).\u003c\/li\u003e\n\u003cli\u003eHeat Pump is equipped with outdoor temperature reset feature.\u003c\/li\u003e\n\u003cli\u003eCarel Controller uses Modbus Protocol (BMS interface cards are available upon request).\u003c\/li\u003e\n\u003cli\u003eDC Inverter Panasonic Compressor with Enhanced Vapor Injection.\u003c\/li\u003e\n\u003cli\u003eUses R32 Refrigerant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=1\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eCSA C22.2 No. 236-15\u003c\/strong\u003e and \u003cstrong\u003eUL 1995:2015 R8.18\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical ATW HP Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAir to Water Heat Pump can be used for various applications that require a Hot or Chilled Heat Transfer fluid. The most common applications are Hydronic Space Heating and Cooling, Domestic Hot Water Pre-Heating, SPA or Pool Heating (when used with\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Titanium Heat Exchanger\" href=\"https:\/\/hydrosolar.ca\/collections\/titanium-pool-heat-exchanger\" target=\"_blank\"\u003eTitanium Heat Exchangers\u003c\/a\u003e) and Process Heating.\u003c\/p\u003e\n\u003cp\u003eThe most common typical installation is with 2 buffer tanks, a three way valve and a circulation pump dedicated for the air to water heat pump:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture_45c58038-3ebc-4994-a6f9-2edc3dda2764.png?v=1718204172\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis configuration is the recommended one for optimizing the performance of the heat pump. In the heating season, it allows the DHW heating tank and the space heating tank to be maintained each at a separate temperature (\u003cem\u003elower temperature for the space heating tank\u003c\/em\u003e). This reduces the power consumption of the heat pump since its power draw decreases when its hot water supply temperature decreases. In the summer season, the above installation with 2 tanks allows the heat pump to produce chilled water for space cooling (Tank T-02) and DHW hot water (Tank T-01). The priority between the two tanks can be selected in the menu of the HP controller.\u003c\/p\u003e\n\u003cp\u003eIn projects where Operating Space Heating temperature is close the DHW heating one and\/or no cooling in the project, one buffer tank can be used:\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture1_58ae9711-469f-40cb-ab9a-389b626fdb3b.png?v=1718204917\"\u003e\u003c\/p\u003e\n\u003cp\u003eIn the above configuration, a buffer tank with indirect coil is needed. The indirect coil will be used to preheat DHW and the tank will be used for space heating and\/or cooling. When Heat pump is in cooling mode, the indirect coil used to preheat DHW is bypassed by an ON\/OFF 3 way valve (managed by the controller of the HP).\u003c\/p\u003e\n\u003ch2\u003eControl and Wiring Interface\u003c\/h2\u003e\n\u003cp\u003eController of the Heat Pump is designed to manage everything between the HP and the two tanks. This includes the 3 way valves, Circulation Pump, Backup heat and the temperature of the two tanks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Capture2_db3fb216-3d37-42cc-915f-164d2f9a06dd.png?v=1718207320\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eHeat Pump has an outdoor temperature sensor and it can be programmed to switch between cooling and heating automatically based on outdoor temperature. It has also the possibility to be managed by a third party controller: It can be turned ON\/OFF via port 7-8, Switched to Cooling via port 7-9 and switched to Heating via port 7-10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eHEATING PERFORMANCE\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/080.jpg?v=1763063362\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCOOLING PERFORMANCE\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/table_7-ton_m.png?v=1729863733\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_REV5.pdf?v=1784128681\" title=\"Manual_English\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_E.png?v=1688147093\" alt=\"Manual_English\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/HSS0306080V3LM_F_REV7.pdf?v=1784128678\" title=\"Manuel\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/M_F.png?v=1688147124\" alt=\"Manual_French\"\u003e\u003c\/a\u003e \u003cspan\u003e \u003c\/span\u003e\u003ca title=\"FIRMWARE\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MS-HP-01-ATW_HP_Firmware_Update.pdf?v=1674157898\" target=\"_blank\"\u003e\u003cimg alt=\"FIRMWARE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_6b72f220-f617-4cf4-9d76-e076d4c06395.png?v=1674157956\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003ca name=\"_Toc61868250\"\u003e\u003c\/a\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e \u003c\/h2\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":47384220532982,"sku":"160104080","price":11579.66,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/air-to-water-heat-pump-5-ton-monoblock-dc-inverter-r32-1242731876.png?v=1780611250"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/HSS060V2.jpg?v=1611368020","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/hydro-solar-air-to-water-heat-pump.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}