{"title":"Residential Forced Air Zoning Control panels","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eForced Air Zoning is crucial for previse control over temperature and humidity accross resiedential or small scale commercial buildings. Zoning controller is the brain that analyse indivdual zone's thermostat reading and command zone damper to deliver the required amount of air flow to the zone, so that zone can be maintained at the right temperature and humidity.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"mdp3-forced-air-zones-control-panel","title":"MDP3 Forced Air Zones Control Panel (Expandable) - Plug in Play 12VDC Dampers Ports","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003e\u003cspan\u003eIntroduction\u003c\/span\u003e\u003c\/h2\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eNew Digi-Zone Panel will control 2 or 3 zones on any HVAC System, up to 3 Stages of heating \/ 2 stages of cooling. MDP3 Ver. 04 also controls heat pumps and dual fuel as well as many geothermal heat pumps. The digital display is a menu driven screen that guides the installer through the settings for each tpye of system as well as accurately sets the timings and sensor temperature settings. This panel is \u003cstrong data-mce-fragment=\"1\"\u003eexpandable up to 103 zones\u003c\/strong\u003e, the most in the industry.\u003cstrong data-mce-fragment=\"1\"\u003eTo add zones, use the \u003cspan data-mce-fragment=\"1\"\u003e\u003ca title=\"MDPA\" href=\"https:\/\/hydrosolar.ca\/products\/mdpa2-forced-air-zones-2-zones-expansion-module-for-mdpe-panel?_pos=1\u0026amp;_sid=75f35f077\u0026amp;_ss=r\" target=\"_blank\" data-mce-href=\"https:\/\/hydrosolar.ca\/products\/mdpa2-forced-air-zones-2-zones-expansion-module-for-mdpe-panel?_pos=1\u0026amp;_sid=75f35f077\u0026amp;_ss=r\" data-mce-fragment=\"1\"\u003eMDPA2\u003c\/a\u003e\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eVer .04 = 2 zone per adder.\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eThe NEW MDP3 Ver. 4 controls only the New Plug-in Zone Motors that use modular cords, supplied with each damper. This panel is used exclusively with the ZDSP, ZDBP, OZD, RDP, RRP and RTP dampers. The MDP3 Ver. 4 panel is designed to use a minimum of wires to make zoning simple and affordable, no matter what type of HVAC system it is used to zone. Each zone can use a standard 4\/5 wire (Y-G-R-W(-C) thermostat for any type of system as the additional controls for staging, etc. are in the MDP3 Ver. 4.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eHeat pump thermostats can also be used when controlling the second stage and emergency heat are desired from the thermostat. All terminal blocks are color coded for each wire and have push–in connections making wiring even simpler and no need for a small screwdriver, as with all other zoning panels. The state of the art surface mount technology for all electronic components makes for a highly reliable control panel.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eThe MDP3 Ver. 4 is an all-in-one zone control panel that has following menu driven set-up features:\u003c\/div\u003e\n\u003c\/li\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eSystem Type = Gas\/Electric or Heat Pump • Heat Pump Type = Conventional or Fossil\/Dual Fuel\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eOutdoor Balance Point (OBP) Adjustable – 5°F -53°F • Thermostat Type – H\/C or HP • HP Stat RV – O or B\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eNumber of Zones – Adjustable 2 to 103 • Fan On In Heat – On or Off\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eFan On In Purge – On or Off\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eEmergency Heat – On or Off • Minimum Compressor On Timer – On (2 mins) or Off\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eStaging – Adjustable Timer, # of zones calling or supply air temperature (stage optimization)\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eChangeover Timer = Adjustable 10-30 Minutes\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eLeaving Air Sensor – Capacity protection to shut off HVAC\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cdiv\u003eCentra-Zone™ - Zone 1 Master Changeover Disabled or Enabled • DS-BK = Switch to low speed based on percentage of zones calling.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTest – Enabled or Disabled\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MDP3_Ver_4_Sell_Sheet.pdf?v=1674499255\" title=\"Submittal\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MDP3_Ver_4_Sell_Sheet.pdf?v=1674499255\" data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_b014b190-e5c4-467a-ad89-7e1392c71e9c.png?v=1647363890\" alt=\"Submittal\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_b014b190-e5c4-467a-ad89-7e1392c71e9c.png?v=1647363890\"\u003e\u003c\/a\u003e\u003ca title=\"Submittal\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MDP3-V4-Installation-Operation-Instructions.pdf?v=1674499256\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MDP3-V4-Installation-Operation-Instructions.pdf?v=1674499256\" data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- more --\u003e\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44833923334390,"sku":"50010101","price":715.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/mdp3-forced-air-zones-control-panel-38532299227382.png?v=1674501170"},{"product_id":"mdpa2-forced-air-zones-2-zones-expansion-module-for-mdpe-panel","title":"MDPA2 -Forced Air 2 Zones Expansion Module for MDP3 Panel  - Plug in Play 12VDC Dampers Ports","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eThe Digi-Zone Adder (MDPA2) for Plug-In Dampers is a two (2) zone control panel that is only used to add one or two additional zones to the MDP3 Zone Panel. A total of fifty (50) MDPA panels may be added to an MDP3 Zone Panel to get up to one hundred and three (103) zones.\u003c\/li\u003e\n\u003cli\u003eWhen installing the MDPA2 panel it is important to pick a central location (typically in close proximity to the MDP3 control panel) where it is most convenient to bring all the wires. Most often this is at the furnace or air handler. It is often closest to power, the HVAC unit controls and the zone dampers when typically located at or near the plenum. However this panel can be located remotely from the main panel and only requires a CAT 5 cable (supplied with MDPA2) in order to place remotely.\u003c\/li\u003e\n\u003cli\u003eThe MDPA2 panel case is made of sturdy ABS plastic and can be mounted to any flat surface. It is recommended that the panel be mounted to a wall or return plenum and NOT on the furnace or plenum where it will be in contact with the hot temperatures.. The panel can be located in an attic space or in an enclosed cabinet of a rooftop unit. Insure the panel is not in direct exposure to the elements.\u003c\/li\u003e\n\u003cli\u003eThe cover easily removes from the case by pulling firmly and separating the cover from the case exposing the circuit board. There are 4 key-hole mounting points in each corner of the case.\u003c\/li\u003e\n\u003cli\u003eThe case has openings in the rear of the case as well as the side for all wiring. Wiring can come from the back as well as the side in order to make a neat installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MDPA2-Installation-Operation-Instructions.pdf?v=1674501610\" target=\"_blank\" title=\"manual\" rel=\"noopener noreferrer\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834018918646,"sku":"50010103","price":444.15,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/mdpa2-forced-air-zones-2-zones-expansion-module-for-mdpe-panel-38532321804534.png?v=1674501711"},{"product_id":"zps-leaving-air-temperature-sensor","title":"ZPS - Plenum Supply Air Temperature Sensor","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eThe Zoning Plenum Sensor, Model ZPS, is a duct mounted sensor used with the ZONEFIRST MasterZone™ Control Panels. The ZPS senses the supply air plenum temperature and protects the furnace, compressor or heat pump from over temperatureas zone dampers close down and air flow may be restricted and especially when a by-pass is used and supply is mixed back into the return air which can cause extreme plenum temperatures. The ZPS protects the equipment by cutting off the heating or cooling call when its limit temperature is reached for either heating or cooling. The ZPS insures the heating and cooling equipment is protected when zoning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/ZPS_000.pdf?v=1674525791\" target=\"_blank\" title=\"Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-selected=\"1\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834568405238,"sku":"50010502","price":64.16,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/zps-leaving-air-temperature-sensor-38532955603190.png?v=1674525830"},{"product_id":"oas-outdoor-air-temperature-sensor","title":"OAS - Outdoor Air Temperature Sensor","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOutdoor Air Sensor, u\u003c\/span\u003e\u003cspan\u003esed with H32, H32P, MDP3 panels to sense outdoor air temperature when controlling dual fuel\/ fossil fuel heat pumps.\u003c\/span\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834586624246,"sku":"50010501","price":61.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/oas-outdoor-air-temperature-sensor-38532968055030.png?v=1674526731"},{"product_id":"t24-120v-to-24v-transformer","title":"T24- 120V to 24V transformer","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eThe T24 is a 120 Volts AC to 24 Volt AC, step-down transformer used to power any of Zone-A-Trol’s dampers and controls. The plate mounted model makes for easy installation on any standard 4”x4” junction box. The 6” leads connect to the 120 Volts for the transformer primary. The screw terminals provide for easy wiring of 18 gauge thermostat wire for any of Zonefirst’s control panels or dampers. The 40VA output can power up to five (5) spring retrun dampers or a control panel with up to four (4) dampers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/T24.pdf?v=1674527130\" target=\"_blank\" title=\"Manual\" rel=\"noopener noreferrer\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-selected=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834597437686,"sku":"50030106","price":74.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/t24-120v-to-24v-transformer-38532975886582.png?v=1674527271"},{"product_id":"h32-2-or-3-zone-heat-pump-dual-fuel-conventional-control-panel","title":"H32 – 2 or 3 Zone Heat Pump, Dual Fuel \u0026 Conventional Control Panel (Not Expandable)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e24V, universal 2 or 3 Zone Panel for Heat Pumps, Dual Fuel and Conventional 2 heat\/ 2 cool.\u003c\/li\u003e\n\u003cli\u003eBuilt in DIP switches that set desired functions for type of HVAC equipment outputs and zone thermostats used.\u003c\/li\u003e\n\u003cli\u003eZPS sensor to provide capacity control of the equipment.\u003c\/li\u003e\n\u003cli\u003eOptional OAS sensor to provide changeover points for dual\/fossil fuel applications.\u003c\/li\u003e\n\u003cli\u003eCompatible with any 4\/5 wire thermostats.\u003c\/li\u003e\n\u003cli\u003eBuilt in LEDs indicate system status and indicators to show each zone’s call.\u003c\/li\u003e\n\u003cli\u003eColor-coded, push-in terminal blocks makes wiring simple and fast.\u003c\/li\u003e\n\u003cli\u003eCompatible with Dampers having 24VAC motors only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"Submittal\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/H32Install.pdf?v=1674527865\" target=\"_blank\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834603827446,"sku":"50010201","price":678.6,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/h32-2-or-3-zone-heat-pump-dual-fuel-conventional-control-panel-38532990861558.png?v=1674528350"},{"product_id":"h32p-2-or-3-zone-heat-pump-dual-fuel-conventional-control-panel","title":"H32P – 2 or 3 Zone Heat Pump, Dual Fuel \u0026 Conventional Control Panel (Not Expandable)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e24V, universal 2 or 3 Zone Panel for Heat Pumps, Dual Fuel and Conventional 2 heat\/ 2 cool.\u003c\/li\u003e\n\u003cli\u003eBuilt in DIP switches that set desired functions for type of HVAC equipment outputs and zone thermostats used.\u003c\/li\u003e\n\u003cli\u003eZPS sensor to provide capacity control of the equipment.\u003c\/li\u003e\n\u003cli\u003eOptional OAS sensor to provide changeover points for dual\/fossil fuel applications.\u003c\/li\u003e\n\u003cli\u003eCompatible with any 4\/5 wire thermostats.\u003c\/li\u003e\n\u003cli\u003eBuilt in LEDs indicate system status and indicators to show each zone’s call.\u003c\/li\u003e\n\u003cli\u003eColor-coded, push-in terminal blocks makes wiring simple and fast.\u003c\/li\u003e\n\u003cli\u003eUsed with RDP, RTP, ZDSP, ZDBP, RRP, \u0026amp; OZD 12VDC Dampers.\u003c\/li\u003e\n\u003cli\u003eAlso available with By-Pass Eliminator (\u003cstrong\u003eH32PB\u003c\/strong\u003e) or with Kit (\u003cstrong\u003eH32PBK \u003c\/strong\u003e– includes BPE, ZPS and T24).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/H32P-Installation.pdf?v=1674528425\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834610807030,"sku":"50010203","price":555.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/h32p-2-or-3-zone-heat-pump-dual-fuel-conventional-control-panel-38532997808374.png?v=1674528891"},{"product_id":"mmz3-2-or-3-zone-single-stage-control-panel-not-expandable","title":"MMZ3 – 2 or 3 Zone Single Stage Control Panel (Not Expandable)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e24V, Single Stage Panel for 2 or 3 Zones.\u003c\/li\u003e\n\u003cli\u003eCompatible with any 4\/5 wire thermostats.\u003c\/li\u003e\n\u003cli\u003eBuilt in LEDs indicate system status and indicators to show each zone’s call.\u003c\/li\u003e\n\u003cli\u003eColor-coded, push-in terminal blocks makes wiring simple and fast.\u003c\/li\u003e\n\u003cli\u003eCompatible with RDS, RTS, ZDS, ZDB 24VAC Dampers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MMZ3Install.pdf?v=1674529689\" target=\"_blank\" title=\"Submittal\" rel=\"noopener noreferrer\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" alt=\"Manual\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834626797814,"sku":"50010301","price":505.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/mmz3-2-or-3-zone-single-stage-control-panel-not-expandable-38533013897462.png?v=1674529972"},{"product_id":"mmp2-2-zone-single-stage-control-panel-not-expandable","title":"MMP2 – 2 Zone Single Stage Control Panel (Not Expandable)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe Mini-MasterZone 2 Zone panel is an economical 2 zone only panel for single stage heating and cooling systems. Compatible with any 4\/5 wire (Y-G-R-C-W) thermostats, this panel is the simplest zoning system yet, needed with Hydro-Air and electric Heating systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in LEDs indicate system status and indicators to show each zone’s call.  This panel features NEW color coded screw-less terminal blocks making wiring quick and simple.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe MMP2 controls only the New Plug-In Dampers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen any zone calls for heating (or cooling), the panel accepts the first call, opens the damper to the calling zone, closes the dampers to the satisfied zones and activates the HVAC Unit. Any calls for the same mode, heating or cooling, will have their zone damper open and receive conditioned air. If an opposite call is made during this time, it will be held until the first mode calling is either satisfied or a maximum of 20 minutes expires, which then after an approximate 2 minute purge time, will switch over and satisfy the opposite call.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnce all heating and cooling calls are satisfied the panel will accept fan only calls and cycle the dampers to supply air only to those zones with the Fan switch in the ON position. If there are no heat, cool or fan only calls, all dampers return to the open position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/NEWMMP2.pdf?v=1674530338\" target=\"_blank\" title=\"Submittal\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834631155958,"sku":"50010303","price":394.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/mmp2-2-zone-single-stage-control-panel-not-expandable-38533020549366.png?v=1674530330"},{"product_id":"mmp3-2-or-3-zone-single-stage-control-panel-not-expandable","title":"MMP3 – 2 or 3 Zone Single Stage Control Panel (Not Expandable)","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Stage Panel for 2 or 3 Zones.\u003c\/li\u003e\n\u003cli\u003eCompatible with any 4\/5 wire thermostats.\u003c\/li\u003e\n\u003cli\u003eBuilt in LEDs indicate system status and indicators to show each zone’s call.\u003c\/li\u003e\n\u003cli\u003eColor-coded, push-in terminal blocks makes wiring simple and fast.\u003c\/li\u003e\n\u003cli\u003eDamper test buttons\u003c\/li\u003e\n\u003cli\u003eUsed with RDP, ZDSP, ZDBP, RTP, RRP, \u0026amp; OZD 24VDC Dampers\u003c\/li\u003e\n\u003cli\u003eAlso available with By-Pass Eliminator (\u003cstrong\u003eMMP3B\u003c\/strong\u003e) or with Kit (\u003cstrong\u003eMMP3BK\u003c\/strong\u003e – includes BPE, ZPS and T24)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"Submittal\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/SubmittalMMZ_MMP3.pdf?v=1674530471\" target=\"_blank\"\u003e\u003cimg alt=\"Submittal\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_b014b190-e5c4-467a-ad89-7e1392c71e9c.png?v=1647363890\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_b014b190-e5c4-467a-ad89-7e1392c71e9c.png?v=1647363890\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Manual_NEWMMP3.pdf?v=1674530471\" target=\"_blank\" title=\"Submittal\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- more --\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44834639020278,"sku":"50010305","price":505.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/mmp3-2-or-3-zone-single-stage-control-panel-not-expandable-38533038244086.png?v=1674530871"},{"product_id":"plug-in-play-cable-for-12vdc-actuators","title":"Plug in Play Cable for 12VDC Actuators","description":"\u003c!-- more --\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eAdditional 25′(PIW25) or 50′ (PIW50) length of modular cord with connectors and coupler for longer damper runs using any Plug-In Damper Motor.\u003c\/span\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"25","offer_id":44865103167734,"sku":"50070301","price":11.72,"currency_code":"CAD","in_stock":true},{"title":"50","offer_id":44865103200502,"sku":"50070302","price":22.82,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/plug-in-play-cable-for-12vdc-actuators-38550329458934.png?v=1674865311"},{"product_id":"by-pass-eliminator","title":"BPE - By-Pass Eliminator","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eTechnical Dcouments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eThe Bypass Eliminator™ (Model BPE) Control is an interface between a ZONEFIRST Zone Control Panel and its zone dampers. The BPE is used to eliminate the need for a traditional separate by-pass duct and damper directed back into the return duct. The BPE can ONLY be used with ZONEFIRST’S Plug-In Zone Dampers and control panels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor Use Only with ZoneFirst’s Plug-In Zone Dampers\u003c\/li\u003e\n\u003cli\u003eMonitors the system’s static pressure\u003c\/li\u003e\n\u003cli\u003eEliminates need for traditional by-pass duct and damper\u003c\/li\u003e\n\u003cli\u003eFour Zone Inputs\u003c\/li\u003e\n\u003cli\u003eControls up to ten dampers per zone\u003c\/li\u003e\n\u003cli\u003eIncludes 10 feet of pressure tubing, duct probe and four 7 foot cables\u003c\/li\u003e\n\u003cli\u003eLCD displays status of zones (Open or Closed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThe Bypass Eliminator™ (Model BPE) Control is an interface between a ZONEFIRST Zone Control Panel and its zone dampers. The BPE is used to eliminate the need for a traditional separate by-pass duct and damper directed back into the return duct. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe BPE can ONLY be used with ZONEFIRST’S Plug-In Zone Dampers and control panels. The BPE uses an air sensor in the duct system on the supply side and before all zone dampers so it can monitor the systems static pressure, whenever the blower is running. The zone dampers are now wired directly into the BPE and not the zone control panel. The BPE has 4 zone inputs where the damper outputs of the zone control panel will plug-in on the BPE. \u003c\/span\u003e\u003cspan\u003eThe zone control panel controls the zone dampers through the BPE. The BPE includes 10 feet of pressure tubing (which can be cut down to size), as well as a duct probe, and four 7 foot telephone cables to interface the BPE with the zone controller. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe BPE controls up to 4 zones on a single HVAC unit and up to 10 dampers per zone on the output terminals. When the BPE gets a signal from the Zone Controller that a zone damper is to be powered open it immediately opens the corresponding zone damper(s) on the output terminals. Anytime the BPE’s pressure sensor detects the pressure in the supply plenum is higher than the Upper Limit Set Point it will modulate the closed zone dampers open to relieve the excess pressure into those zones. As these dampers modulate open the air pressure will drop below the high set-point and the zone dampers stop. When the BPE’s pressure sensor is below than the Lower Limit Set Point it will close the zone dampers. Once the pressure has equalized to higher than the Lower Limit set point and lower than the Upper Limit set point the BPE will signal the dampers to stay in their current position. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe LCD Display will display the status of the zones OP (open), CL (closed), or a number from 01 to 99 to indicate what percent the zones that were in the closed position were modulated open in order to relieve the excess air from the ductwork. If a zone is available for modulation that means that the Zone control board is sending a close signal to the BPE. In the upper right hand corner the display will read P in with the pressure reading being displayed just below it.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/BPE_Sell_Sheet.pdf?v=1675366597\" title=\"SELL SHEET\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_3_aa4b5e16-719c-49a1-9f3a-b954c6c3f91d.png?v=1674923229\" alt=\"SUBMITTAL\"\u003e\u003cimg alt=\"MANUAL\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_4.png?v=1674923269\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_4.png?v=1674923269\"\u003e\u003c\/a\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":44876950733046,"sku":"50090101","price":715.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/bpe-by-pass-eliminator-38569836871926.png?v=1675367331"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/collections\/MDP3_Panel.png?v=1674499713","url":"https:\/\/hydrosolar.ca\/en-us\/collections\/residential-forced-air-zones-control-panels.oembed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}