{"product_id":"air-cooled-chiller-simultaneous-heating-cooling-capacity-5-ton","title":"Air Cooled Chiller, Simultaneous Heating \u0026 Cooling, Capacity 5 Ton","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eEquipment\u003c\/li\u003e\n\u003cli\u003eControls, Safeties \u0026amp; Operating Characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eEquipment\u003c\/h2\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (Ton)\u003c\/td\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaterial Submittal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eO\u0026amp;M Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eMHRC2-060-VS-01\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHRC2-060-VS-01_Submittal_Rev._1.36.pdf?14797611072935121349\" title=\"Material Submittal\" target=\"_blank\"\u003e\u003cimg height=\"129\" width=\"100\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_19.png?v=1707320513\" alt=\"Material Submittal\" style=\"display: block; margin-left: auto; margin-right: auto;\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_19.png?v=1707320513\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHRC2_Operation_Manual_Rev62016NRC.pdf?14797611072935121349\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/8.png?v=1707225494\" width=\"100\" height=\"129\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eA. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested air-cooled liquid chiller.\u003c\/li\u003e\n\u003cli\u003eUnit is assembled on heavy gauge steel mounting\/lifting rails.\u003c\/li\u003e\n\u003cli\u003eContained within the unit cabinet shall be all factory wiring, piping, controls, refrigerant charge (R410a), POE oil and special accessories required prior to start up.\u003c\/li\u003e\n\u003cli\u003eBrass body strainer with 20 mesh screen and blow down is supplied in cabinet as a field installable accessory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCapable of withstanding 500-hour salt spray test in accordance with the ASTM (USA) standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Condenser Fan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFive blade glass reinforced polypropylene (PPG) petals mounted on a cast aluminum hub construction and shall be dynamically balanced and corrosion resistant.\u003c\/li\u003e\n\u003cli\u003eVertical discharged air.\u003c\/li\u003e\n\u003cli\u003eMotors and blades shall be protected by coated steel wire safety guards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser fan motor is variable speed, brushless DC control.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed Air Over (TEAO), use class B insulation, and permanently lubricated ball and\/or sleeve bearings.\u003c\/li\u003e\n\u003cli\u003eFan motors are internally overload protected with automatic reset.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. Compressors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit contains one Emerson\/Copeland variable speed DC scroll compressor.\u003c\/li\u003e\n\u003cli\u003eDirect current DC, 900-7,200 RPM (15-120 HZ).\u003c\/li\u003e\n\u003cli\u003eCompressor motor is suction gas cooled.\u003c\/li\u003e\n\u003cli\u003eExternal motor protection.\u003c\/li\u003e\n\u003cli\u003eExternally protected by low and high pressure cutout devices and discharge temperature sensing thermistor.\u003c\/li\u003e\n\u003cli\u003eIndividual vibration isolators.\u003c\/li\u003e\n\u003cli\u003eCompressor compartment is internally insulated using noise reducing elastomeric foam insulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Pump:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit shall not be capable of incorporating a field installed chilled liquid solution pump internally (Space restricted).\u003c\/li\u003e\n\u003cli\u003eUnit has chilled liquid solution piping to the exterior of the cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Evaporator (Cooling):\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEvaporator has one refrigerant circuit and one liquid solution circuit.\u003c\/li\u003e\n\u003cli\u003eRated for a refrigerant side working pressure of 550 psig and a maximum water side working pressure of 150 psig.\u003c\/li\u003e\n\u003cli\u003eSingle pass, ANSI type 316 stainless steel, brazed plate construction with Copper\/Nickel brazing material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH. Condenser (Heating):\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser has one refrigerant circuit and one liquid solution circuit.\u003c\/li\u003e\n\u003cli\u003eRated for a refrigerant side working pressure of 550 psig and a maximum water side working pressure of 150 psig.\u003c\/li\u003e\n\u003cli\u003eSingle pass, ANSI type 316 stainless steel, brazed plate construction with Copper\/Nickel brazing material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eI. Evaporator\/Condenser (Cooling\/Heating):\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser coil shall be air-cooled with integral sub-cooler.\u003c\/li\u003e\n\u003cli\u003eConstructed of rifled copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eCleaned and dehydrated.\u003c\/li\u003e\n\u003cli\u003eFactory leak tested to 650 psig.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eI. Refrigerant Circuits:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEach circuit shall contain a liquid strainer, electronic expansion valve, solenoid valve, check valve, refrigerant charge of R410a and POE compressor oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch2\u003eControls and Safeties\u003c\/h2\u003e\n\u003ch4\u003eControls\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChiller is completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eTemperature control is based on leaving liquid solution temperature or storage tank. Temperature accuracy shall be + - 1°F.\u003c\/li\u003e\n\u003cli\u003econtrol is variable speed control.\u003c\/li\u003e\n\u003cli\u003eControls includes the following components: 24vac transformer to serve all controllers relays and control components, Microprocessor based liquid solution temperature controller, Leaving water temperature thermistor, Pump bypass timer, Compressor recycle timer, Optional low pressure bypass timer for low ambient operation, Optional fan cycling control for low ambient operation, Chilled liquid solution flow switch.\u003c\/li\u003e\n\u003cli\u003eAll functions are addressable, logic, code and algorithm controlled.\u003c\/li\u003e\n\u003cli\u003eSuppliedwith Ethernet port for communication and monitoring.\u003c\/li\u003e\n\u003cli\u003eCompatible with Building Automation System (BAS) using BACnet protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSafeties\u003c\/h4\u003e\n\u003cp\u003eUnit is equipped with tall necessary components in conjunction with control system to provide the following protection:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow refrigerant pressure.\u003c\/li\u003e\n\u003cli\u003eHigh refrigerant pressure.\u003c\/li\u003e\n\u003cli\u003eWater side Cold \u0026amp; Hot Flow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOperating Characteristics:\u003c\/h2\u003e\n\u003ch4\u003eTemperatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is capable of starting and running at outdoor temperatures from 0°F (-18\u003cspan\u003e°C)\u003c\/span\u003e to 120°F (49\u003cspan\u003e°C)\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eUnit is capable of starting up, in Cooling Mode, with a maximum 80°F and ambient temperature not above 95\u003cspan\u003e°F.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaximum sustained return fluid solution temperature to the evaporator shall not exceed 70°F in cooling mode.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eMinimum 10% Propylene Glycol solution is always required in all applications. \u003c\/li\u003e\n\u003cli\u003eFor outdoor temperatures below 32°F, reference MAC Glycol Solution Data table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary electrical power supply shall enter the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply shall be rated to withstand 90°C operating ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Hydro Solar Solutions","offers":[{"title":"5 Ton \/ 208\/230-50\/60 Single Phase","offer_id":12583436615741,"sku":"33040517","price":44180.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/5-ton-208-230-50-60-single-phase-air-cooled-chiller-simultaneous-heating-cooling-capacity-5-ton-3969132625981.jpg?v=1578948637","url":"https:\/\/hydrosolar.ca\/en-us\/products\/air-cooled-chiller-simultaneous-heating-cooling-capacity-5-ton","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}