{"product_id":"fan-coil-unit-mhccw-10-00-2-5-ton-2-pipes-chilled-hot-water-ceiling-concealed","title":"Fan Coil Unit - MHCCW-10-00, 2.5 ton, 2 Pipes Chilled\/Hot Water Ceiling Concealed","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eA. General:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is factory assembled and tested chilled or hot water fan coil with electric heat (Optional).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnit is assembled with heavy gauge galvanized steel.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to s tart up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eC. Fan Motors :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIs available in 208\/230-1-50\/ 60 VAC configuration.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan motors has three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eD. Blower Wheels :\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eE. Water Coil:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManufactured with water coils containing 3\/8” copper tubing mechanically bonded to aluminum fins .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eContain both a manual water drain and manual air bleed port per coil.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoils are capable of being field converted from right to left hand connection (only for 1 to 3 Ton MHCCW Units).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eF. Drain Pan:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePans contain a left and right hand primary s loped drain connection as well as a sloped right hand secondary drain connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eG. Electric Heat\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e(only for 1 to 3 Ton MHCCW Units)\u003c\/span\u003e:\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectric Heaters are of the rod and disk type.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eand are protected by safeties .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eH. Controls\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAll components are wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControls include the following components: 24vac trans former, Fan relays, Electric heat sequencers (\u003cspan data-mce-fragment=\"1\"\u003eonly for 1 to 3 Ton MHCCW Units\u003c\/span\u003e), Optional Thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eI. Safeties\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coil is equipped with all necessary components in conjunction with the control system to provide the following protections: High temperature, Over current protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eJ. Electrical Requirements\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eElectrical power supply is rated to withstand 120°F operating ambient \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003etemperatures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eK. Enclosures (Optional)\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFan coils are capable of incorporating field assembled enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnclosures are internally insulated to ensure quite operation and increase efficiency.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude knockouts for ease of piping and electrical in and out of the enclosures .\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude an optional return air cutout in the enclosure.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclude a supply air duct flange.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncorporate baked polyester powder service access panels with and without a filtered louver.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MHCCW-1_nomenclature.jpg?v=1647030374\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-10-00_Submittal_Rev2.pdf\" title=\"Technical Manual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\" alt=\"technical documents\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Technical_Manual_240Wide.png?v=1631842262\"\u003e\u003c\/a\u003e\u003ca title=\"O \u0026amp; M Manual\" href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW_IOM_220V_Rev1.2.pdf\" target=\"_blank\"\u003e\u003cimg alt=\"Manual\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/O_M_Manual_4ec73a5f-6b7f-4be2-9a02-ce4fbe9199b6.png?v=1638147926\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MHCCW-10-00_Wiring_Diagram__Dimensional_Drawing_Rev._1.1.pdf\" title=\"wiring\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\" alt=\"wiring\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Wiring_Diagram_Logo.png?v=1646759200\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Default Title","offer_id":42710069608694,"sku":"470523010000","price":2513.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/fan-coil-unit-mhccw-10-00-2-5-ton-2-pipes-chilled-hot-water-ceiling-concealed-36763718648054.png?v=1647031014","url":"https:\/\/hydrosolar.ca\/en-us\/products\/fan-coil-unit-mhccw-10-00-2-5-ton-2-pipes-chilled-hot-water-ceiling-concealed","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}