{"product_id":"hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-3-ton-capacity","title":"Hydronic Fan Coil Unit | Cased \u0026 Concealed, 4 Pipe System 208\/230V, 3 Ton Capacity","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eSpecifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNomenclature\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch4\u003e A. General:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUnit is factory assembled and tested chilled and hot water fan coil and  assembled with heavy gauge galvanised steel.\u003c\/li\u003e\n\u003cli\u003eContained with the unit are all factory wiring, piping, associated controls and special accessories required prior to start up. Filters are not included with the fan coil.\u003c\/li\u003e\n\u003cli\u003eA filter rack is built into the return of each fan coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Unit Cabinet:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eComposed of heavy gauge galvanized steel casing with a baked polyester powder.\u003c\/li\u003e\n\u003cli\u003eCabinet is internally insulated to ensure quiet operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Fan Motors:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eis available in 208\/230-1-50\/60Hz.\u003c\/li\u003e\n\u003cli\u003eFan motors is three speed, direct drive, and PSC type.\u003c\/li\u003e\n\u003cli\u003eTotally enclosed.\u003c\/li\u003e\n\u003cli\u003eInternal overload protected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eD. Blower Wheels:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBlower wheels are forward curved and dynamically balanced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eE. External Static Pressure\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Static Unit is rated for a max external static pressure of .5” WG.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow Static Unit \u003c\/span\u003e\u003cspan\u003eis\u003c\/span\u003e\u003cspan\u003e rated for a max external static pressure of .3” WG.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eF. Water Coil:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured with water coils containing 3\/8 copper tubing mechanically bonded to aluminum fins.\u003c\/li\u003e\n\u003cli\u003eContain both a manual water\/ air bleed port per coil.\u003c\/li\u003e\n\u003cli\u003eCoils are factory tested to 350 psig.\u003c\/li\u003e\n\u003cli\u003eCoils have a max operating pressure of 200 PSI.\u003c\/li\u003e\n\u003cli\u003eMaximum liquid solution temperature is 180 degrees F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eG. Drain Pan:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll drain pans are coated on both the interior and exterior with baked polyester powder to resist corrosion.\u003c\/li\u003e\n\u003cli\u003eThe exterior of all drain pans is insulated with closed cell insulation to prevent condensation.\u003c\/li\u003e\n\u003cli\u003ePans contains sloped drain connection as well as a sloped secondary drain connection.\u003c\/li\u003e\n\u003cli\u003eField supplied and installed P-Traps are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eH Controls:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coils are completely factory wired and tested.\u003c\/li\u003e\n\u003cli\u003eAll components are wired to an internal terminal block to allow for a field installed 24 vac\u003c\/li\u003e\n\u003cli\u003ethermostat and or fan speed control.\u003c\/li\u003e\n\u003cli\u003eControls shall include the following components: 24vac transformer, Three fan relays and Optional thermostats.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4\u003eI Power and Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFan coil contains a non-reusable fuse on the secondary voltage side of the transformer.\u003c\/li\u003e\n\u003cli\u003ePrimary electrical power supply enters the unit at a single location.\u003c\/li\u003e\n\u003cli\u003eElectrical power supply is rated to withstand 120°F operating ambient temperatures.\u003c\/li\u003e\n\u003cli\u003eControl and high voltage points are accessed through terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cimg alt=\"Nomenclature\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/MCFCW-1_nomenclature.jpg?v=1647307347\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12-4LS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_0dfaa6fe-5c84-43d7-bd97-579c107978ba.png?v=1647307374\" alt=\"FCU\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12-4HS-1_Submittal_rev1.3.pdf\" title=\"Submittal\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_6f549845-8a43-434e-beb7-bab9d64c0add.png?v=1647307380\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW-12_Wiring_Diagram__Dimensional_Drawing.pdf\" title=\"Submittal\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\" alt=\"Wiring Diagram\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1.png?v=1647308229\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/multiaqua.com\/wp-content\/uploads\/MCFCW_IOM.pdf\" title=\"O\u0026amp;M Manual\" target=\"_blank\"\u003e\u003cimg alt=\"FCU\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_962c143d-be16-4728-95d1-009109e43a36.png?v=1647307385\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"3 Ton \/ Low Static","offer_id":42742665478390,"sku":"480607124","price":4411.79,"currency_code":"USD","in_stock":true},{"title":"3 Ton \/ High Static","offer_id":42742665511158,"sku":"4808091241","price":4601.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-3-ton-capacity-36775803420918.png?v=1647309472","url":"https:\/\/hydrosolar.ca\/en-us\/products\/hydronic-fan-coil-unit-cased-concealed-4-pipe-system-208-230v-3-ton-capacity","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}