{"product_id":"liiquid-to-water-dc-inverter-heat-pump-geo040v1lm-40-mbh-131-f-hot-water","title":"Liquid to Water DC Inverter Heat Pump GEO040V1LM - 40 MBH, 131°F Hot Water","description":"\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCapacities\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Documents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eVersatile Liquid to Water Geothermal heat pumps with DC inverter Panasonic Compressor and Carel Controller using Modbus Protocol. Heat Pump can be used for Open and Closed Loop Geothermal. The Ground Loop Heat Exchanger can be made of copper or titanium. Titanium would be used in open loop configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUses Low Global Warming Potential (GWP) \u003cstrong\u003eR32\u003c\/strong\u003e Refrigerant.\u003c\/li\u003e\n\u003cli\u003eHot Water Supply Temperature from 3\u003cspan\u003e5°C \/ 95°F\u003c\/span\u003e to 55°C \/ 131°F\u003c\/li\u003e\n\u003cli\u003eChilled Water Supply Temperature from 7\u003cspan\u003e°C \/ 44.6°F\u003c\/span\u003e\u003cspan\u003e to 12°C \/ 53.6°F\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eNominal Capacity 40 MBH\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Supply 220-240\/1\/60.\u003c\/li\u003e\n\u003cli\u003eSpace Heating and Space Cooling function.\u003c\/li\u003e\n\u003cli\u003eDedicated Domestic Hot Water (DHW) Pre-Heating Function (Up to 55°C \/ 131°F). HP can go 100% of its capacity into DHW mode.\u003c\/li\u003e\n\u003cli\u003eHeat Recovery function.\u003c\/li\u003e\n\u003cli\u003eHeat Pump can be configured for a 2 Pipe or 4 Pipe System in Combination with DHW Pre-Heating.\u003c\/li\u003e\n\u003cli\u003eHeat Pump has the option of having a titanium \u003cspan\u003eGround Loop Heat Exchanger, which allows it to be used for dumping cooling heat into a swimming pool or hot tub.\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHPs are shipped with WIFI adapter for easy monitoring and remote diagnostics.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72301200?locale=en\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003eCertification\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"CSA Certification Link\" href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.certipedia.com\/certificates\/72228264?locale=en\u0026amp;page_number=3\" title=\"CSA Certification Link\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e: \u003cstrong\u003eUL 60335-1:2016\u003c\/strong\u003e, \u003cstrong\u003eUL 60335-2-40:2022\u003c\/strong\u003e, \u003cstrong\u003eCAN\/CSA-22.2 NO. 60335-1:16 (R2021)\u003c\/strong\u003e, \u003cstrong\u003eCSA C22.2 No. 60335-2-40:22\u003c\/strong\u003e,\u003cstrong\u003e \u003ca href=\"https:\/\/www.energystar.gov\/productfinder\/product\/certified-geothermal-heat-pumps\/details\/4710774\" target=\"_blank\" title=\"ENERGY STAR\" rel=\"noopener\"\u003eEnergy Star\u003c\/a\u003e \u003c\/strong\u003e\u0026amp; \u003cstrong\u003eAHRI\u003c\/strong\u003e.\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eSpace Heating or Cooling and Domestic Hot Water Pre-Heating (DHW) - 2T3AP1T\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIn this configuration, Heat Pump is connected to two separate buffer tanks: one dedicated for DHW Preheating and the other tank dedicated for either space heating in winter or space cooling in the summer. In this operating mode, priority for tank T-01 and T-02 can be set up via the control interface of the heat pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/1_1eb4653b-0fe2-4af2-a963-38ebc7bb6a14.png?v=1706038397\" alt=\"SCHEMATICS\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpace Heating and Domestic Hot Water Pre-Heating (DHW) or Space Cooling - 1T3AP1T\u003c\/h3\u003e\n\u003cp\u003eIn this configuration, Heat Pump is connected to only one buffer tank with an indirect coil: the indirect coil will be used to preheat DHW when HP is in heating mode (when in cooling mode, indirect coil will be bypassed via the three-way valve). Tank will be heated in heating mode and cooled in cooling mode.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"schematics\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/2_370bf6b1-0b01-48b4-b19a-b594050b495e.png?v=1706039093\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSimultaneous Heating and Cooling and\/or Domestic Hot Water Pre-Heating (DHW) - 2T3AP3T\u003c\/h3\u003e\n\u003cp\u003eIn this configuration, Heat Pump works in heating mode only, extracting heat from the chilled water tank and dumping that heat into the hot water tank. Hot Water tank shall have an indirect coil if used to preheat DHW beside space heating.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"schematics\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/3_62ec58be-9ff1-4061-9d5a-d67b0b1355e3.png?v=1706039346\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSimultaneous Heating and Cooling and Domestic Hot Water Pre-Heating (DHW) - 3T3AP3T\u003c\/h3\u003e\n\u003cp\u003eIn this configuration, Heat Pump works in heating mode only, extracting heat from the chilled water tank and dumping that heat into either the space heating tank or DHW\u003cbr\u003epreheating tank.\u003cbr\u003e\u003cimg alt=\"schematics\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/4_ecdcac01-b1a2-4547-9453-a6a1ce2ea2dd.png?v=1706039485\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eHeating and Cooling or Domestic Hot Water Pre-Heating (DHW) - 2T3AP2T\u003c\/h3\u003e\n\u003cp\u003eIn this configuration, Heat Pump is connected to two separate buffer tanks: one dedicated for space heating hot water and the other dedicated for space cooling chilled water. In this operating mode, priority for tank T-01 and T-02 can be set up via the control interface of the heat pump.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/5_479f08c8-f7b8-40b1-8f4f-6bce29db3b5b.png?v=1706040045\" alt=\"schematics\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSpace Cooling and Swimming Pool Heating (DHW) - 1T2AP1T\u003c\/h3\u003e\n\u003cp\u003eIn this configuration, Heat Pump is connected to one buffer tank used for space cooling on the indoor loop side. The outdoor loop side will be hooked up to swimming pool directly with a hydraulic separator or by-pass (\u003cem\u003ethe nominal flow on the ground loop side might be lower than the nominal flow of the swimming pool pump\u003c\/em\u003e).\u003c\/p\u003e\n\u003cp\u003e \u003cimg alt=\"schematics\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/6_33e573ce-ff88-40ee-afbe-78ed0075f711.png?v=1706040126\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003eTitanium Ground Loop Heat Exchanger\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/c40.png?v=1706040377\" alt=\"capacities\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCopper Ground Loop Heat Exchanger\u003c\/span\u003e\u003c\/h3\u003e\n\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/GEO040.jpg?v=1776782416\" alt=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Geothermal_HP_Brochure_2026-04-09.pdf?v=1776707167\" title=\"data sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"258\" width=\"200\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_1_9a0e10dd-4d76-44e5-bd55-1d99afbdc17f.png?v=1776707187\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/GEO0406080V1LM__Titanium_REV4.pdf?v=1777057815\" title=\"data sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"258\" width=\"200\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_3_f3d577ca-1bbf-49e1-b3a0-6a0aed6b4214.png?v=1776707407\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/GEO0406080V1LM__Copper_REV0.pdf?v=1777057835\" title=\"data sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"258\" width=\"200\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/Submittal_2_b67cfe23-a7ff-4610-8ca6-d0e0579a4684.png?v=1776707406\"\u003e\u003c\/a\u003e\u003ca title=\"data sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/GEO0406080V1LM_REV3.pdf?v=1755875708\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/GEO0406080V1LM_REV2_1bf099c9-00c1-4146-acf9-c280c9775d77.pdf?v=1727115669\" title=\"data sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydro Solar Innovative Energy","offers":[{"title":"Coax Shell and Tube - Titanium","offer_id":50129856528630,"sku":"31010102","price":5921.42,"currency_code":"USD","in_stock":true},{"title":"Plate - Copper","offer_id":50129856561398,"sku":"31010101","price":5921.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0010\/8458\/8093\/files\/liquid-to-water-dc-inverter-heat-pump-geo040v1lm-40-mbh-131-f-hot-water-1264126288.png?v=1792700468","url":"https:\/\/hydrosolar.ca\/en-us\/products\/liiquid-to-water-dc-inverter-heat-pump-geo040v1lm-40-mbh-131-f-hot-water","provider":"Hydro Solar Innovative Energy","version":"1.0","type":"link"}