EVI DC INVERTER SPLIT TYPE AIR TO WATER HEAT PUMP - MODEL HSS060V2LS - OPERATING TEMPERATURES -25⁰C TO +45⁰C

Accepted Payment Methods:  Credit Cards paypal bank transfer

Return Policy: We accept return within 30 days of receipt of your orders. Restocking fee applies on some returned Products. Returned Items shall have intact labels, packages and shall not have been used. for more info....

  • refund Full refund if you do not receive your ordered items. 
  • refund Partial Refund for partially not received or partially damaged items

INTRODUCTION

Air to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and reject the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool/heat water or water/glycol fluid mixture. Our EVI DC INVERTER Split Series Air to Water Heat Pumps can work at outdoor temperatures ranging between -25⁰C and +45⁰C.

SPECIFICATIONS

Model Number

HSS060V2LS

Properties

SI

Unit

IP

Unit

 

Outdoor 86°F (30°) DB / 73°F (23°C) WB - Fluid Supply/Return Temperatures 44.6°F (7°C)/54.32°F (12°C)

Nominal Cooling Capacity

13.6

KW

46401

BTU/HR

COP / EER

3.09

KW Out /KW In

10.55

MBH Out /KW In

Min/Max Cooling Capacity

6.26/13.61

KW

21357/46401

BTU/HR

Min/Max Power Input

1.396/4.668

KW

1.396/4.668

KW

Min/Max COP / EER

2.91/4.48

KW Out /KW In

9.93/15.3

MBH Out /KW In

 

Outdoor 95°F (35°) DB / 75°F (24°C) WB - Fluid Supply/Return Temperatures 44.6°F (7°C)/54.32°F (12°C)

Nominal Cooling Capacity

12.4

KW

42307

BTU/HR

COP / EER

2.48

KW Out /KW In

8.47

MBH Out /KW In

Min/Max Cooling Capacity

5.69/12.37

KW

19413/42307

KW

Min/Max Power Input

1.649/5.305

KW

1.649/5.305

KW

Min/Max COP / EER

2.33/3.45

KW Out /KW In

7.84/11.8

MBH Out /KW In

 

Outdoor 44.6°F (7°) DB / 42.8°F (6°C) WB - Fluid Supply/Return Temperatures 95°F (35°C)/86°F (30°C)

Nominal Heating Capacity

18.8

KW

64142

BTU/HR

COP

4.39

KW Out /KW In

4.39

KW Out /KW In

Min/Max Heating Capacity

8.648/18.8

KW

BTU/HR

Min/Max Power Input

1.576/4.282

KW

1.576/4.282

KW

Min/Max COP

4.39/5.49

KW Out /KW In

4.39/5.49

KW Out /KW In

 

Outdoor 44.6°F (7°) DB / 42.8°F (6°C) WB - Fluid Supply/Return Temperatures 113°F (45°C)/104°F (40°C)

Nominal Heating Capacity

17.7

KW

60389

BTU/HR

COP

3.4

KW Out /KW In

3.4

KW Out /KW In

Min/Max Heating Capacity

8.13/17.67

KW

27738/60389

BTU/HR

Min/Max Power Input

1.949/5.032

KW

1.949/5.032

KW

Min/Max COP

3.51/4.17

KW Out /KW In

3.51/4.17

KW Out /KW In

Power Supply (V/Ph/Hz)

220-240/1/60

Rated Current (Amp)

20.5

Maximum Current (Amp)

29.71

Refrigerant Type

R410A

Compressor

Twin Rotary

Condenser Fan Quantity

2

Condenser Fan Airflow

5500

m³/hr

3235

ft³/min

Condenser Fan Rated Power

210

Watt

210

Watt

Fluid Side Heat Exchanger Type

Plate Heat Exchanger

Fluid Side Pressure Drop

25

Kpa

8.365

ft of Water

Fluid Piping Connection Size

1"

Refrigerant Piping Connection Size

φ19 / φ12.7

mm x mm

3/4 x 1/2

in x in

Allowable Water Flow (Min / Rated / Max)

0.56/0.9/1.5

L/s

8.88/14.26/23.77

US gpm

Noise Level

63

Expansion Tank Size

5

L

1.33

US Gallon

Electric Heater Heating Capacity

3

KW

10236

BTU/HR

Grundfos Inverter Pump Model

UPMGEO 25-85-130

Outdoor Unit Dimensions (LxDxH)

1100x490x1350

mm x mm x mm

44x22x54

in x in x in

Indoor Unit Dimensions (LxDxH)

550x325x650

mm x mm x mm

22x13x26

in x in x in

Outdoor Unit Weight

124

Kg

273

Lb

Indoor Unit Weight

27

Kg

60

Lb

Notes

 

 

 

 

DB: Outdoor Dry Bulb Temperature

WB: Outdoor Wet Bulb Temperature

COP: Coefficient of Performance = Heat Output in KW / Power Input in KW

EER: Energy Efficiency Ratio = Heat Output in MBH (1000 x Btu/hr) / Power Input in KW


HEATING PERFORMANCE

HSS060V2LS

Outdoor Air DB Temperature (°C)

Outdoor Air DB Temperature (°F)

Supply Water Temperature 95°F (35°C) / Return Water Temperature 86°F (30°C)

Supply Water Temperature 113°F (45°C) / Return Water Temperature 104°F (40°C)

Supply Water Temperature 131°F (55°C) / Return Water Temperature 122°F (50°C)

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

-25

-13

7

23,883

3.32

2.11

6.67

22,757

3.91

1.71

7.6

25,930

4.88

1.56

 -20 

-4

12.11

41,317

4.89

2.48

10.26

35,006

4.82

2.13

10.7

36,507

6.05

1.77

 -15 

5

14.76

50,359

5.06

2.92

12.51

42,682

5.05

2.48

12.74

43,467

6.47

1.97

 -7 

19.4

15.16

51,723

4.41

3.44

14.72

50,222

5.22

2.82

14.98

51,109

6.69

2.24

 2 

35.6

17.84

60,867

4.78

3.74

17.32

59,093

5.22

3.32

17.63

60,151

7.09

2.49

 7 

44.6

18.8

64,142

4.23

4.45

17.67

60,287

4.91

3.6

18.56

63,324

6.28

2.96

 12 

53.6

19.74

67,349

4.08

4.85

18.56

63,324

4.64

4

19.48

66,462

5.94

3.28

 20 

68

20.73

70,727

3.82

5.43

19.48

66,462

4.24

4.6

20.46

69,806

5.43

3.77



 

Technical Documents

PDF Technical Manual