  • Specifications
  • Nomenclature
  • Technical Documents
  • A. General:

    • Unit shall be a factory assembled and tested water fan coil.
    • Unit shall be assembled with high quality.
    • Contained within the unit shall be all factory wiring, piping, and associated controls.
    • Unit Includes 24V Transfromer and fan relays for field installed thermostat.

    B. Unit Cabinet and Cover:

    • Cabinet is constructed of galvanized sheet metal.
    • Cover composed of high impact polymers.
    • Internally and externally insulated to ensure quiet operation.

    C. Fan Motor and Blower Wheels:

    • Available in 208/230-1-50/60 VAC.
    • Fan motor has three speed, direct drive, and PSC type.
    • Fan motor is totally enclosed.
    • Fan motor is internal overload protected.
    • Radial blower wheel is dynamically balanced.

    D. Air Distribution:

    • Unit contains four manually adjustable discharge air louvers.

    E. Water Coil:

    • Manufactured with water coils containing copper tubing mechanically bonded to aluminum fins.
    • Coils are factory tested to 300 psig.
    • Coils are designed to accept an entering water temperature not to exceed 160°F
    • Pressure independent flow control required on both coils to not exceed max flow for each coil. Consult primary coil and secondary coil data for proper sizing

    F. Drain Pan:

    • Constructed of injected molded polystyrene.

    G. Filters:

    • Unit contains a woven panel washable filter.

    H. Fresh Air:

    • Unit is able to receive up to 50% filtered fresh air.
    • Fresh air introduced is externally fan forced and externally controlled.

    I Power & Safety:

    • Fan coils are factory wired and tested.
    • Unit includes a terminal block that is capable of incorporating a 24 vac, field supplied, hard wired thermostat.
    • Fan coil contains a renewable fuse on the low voltage side of the transformer.
    • Coils is designed to accept an entering water temperature not to exceed 160°F
  • FCU