Hydro Solar and COVID-19: We remain fully operational serving our customers all over Canada and the US. 

0

Your Cart is Empty

MONOBLOCK DC INVERTER AIR TO WATER HEAT PUMP - MODEL HSS030V2 - OPERATING TEMPERATURES -20⁰C TO +45⁰C

Accepted Payment Methods:  Credit Cards paypal bank transfer

Return Policy: We accept return within 30 days of receipt of your orders. Restocking fee applies on some returned Products. Returned Items shall have intact labels, packages and shall not have been used. for more info....

  • refund Full refund if you do not receive your ordered items. 
  • refund Partial Refund for partially not received or partially damaged items

INTRODUCTION

Air to Water Heat Pump is a closed loop thermal device that draws heat from one place (called heat source) and reject the drawn heat to another place (called heat sink). Unlike conventional air to air heat pump, where generated thermal energy is used to cool/heat air fluid, Air to Water Heat Pumps use generated thermal energy to  cool/heat water or water/glycol fluid mixture. Our Monoblock Series Air to Water Heat Pumps can work at outdoor temperatures ranging between -20⁰C and +45⁰C.

SPECIFICATIONS

Model Number

HSS030V2

Properties

SI

Unit

IP

Unit

 

Outdoor 86°F (30°) DB / 73°F (23°C) WB - Fluid Supply/Return Temperatures 44.6°F (7°C)/54.32°F (12°C)

Nominal Cooling Capacity

7.4

KW

25248

BTU/HR

COP / EER

3.28

KW Out /KW In

11.2

MBH Out /KW In

Min/Max Cooling Capacity

3.39/7.37

KW

11566/25248

BTU/HR

Min/Max Power Input

0.715/2.347

KW

0.715/2.347

KW

Min/Max COP / EER

3.14/4.74

KW Out /KW In

10.71/16.17

MBH Out /KW In

 

Outdoor 95°F (35°) DB / 75°F (24°C) WB - Fluid Supply/Return Temperatures 44.6°F (7°C)/54.32°F (12°C)

Nominal Cooling Capacity

6.7

KW

22860

BTU/HR

COP / EER

2.62

KW Out /KW In

8.94

MBH Out /KW In

Min/Max Cooling Capacity

3.08/6.7

KW

10507 / 22860

BTU/HR

Min/Max Power Input

0.845/2.667

KW

0.845/2.667

KW

Min/Max COP / EER

2.51/3.65

KW Out /KW In

8.56/12.45

MBH Out /KW In

 

Outdoor 44.6°F (7°) DB / 42.8°F (6°C) WB - Fluid Supply/Return Temperatures 95°F (35°C)/86°F (30°C)

Nominal Heating Capacity

9.5

KW

32413

BTU/HR

COP

4.45

KW Out /KW In

4.45

KW Out /KW In

Min/Max Heating Capacity

4.37/9.5

KW

14910/32413

BTU/HR

Min/Max Power Input

0.786/2.135

KW

0.786/2.135

KW

Min/Max COP

4.45/5.56

KW Out /KW In

4.45/5.56

KW Out /KW In

 

Outdoor 44.6°F (7°) DB / 42.8°F (6°C) WB - Fluid Supply/Return Temperatures 113°F (45°C)/104°F (40°C)

Nominal Heating Capacity

8.9

KW

30366

BTU/HR

COP

3.6

KW Out /KW In

3.6

KW Out /KW In

Min/Max Heating Capacity

4.11/8.93

KW

14022/30366

BTU/HR

Min/Max Power Input

0.972/2.508

KW

0.972/2.508

KW

Min/Max COP

3.56/4.23

KW Out /KW In

3.56/4.23

KW Out /KW In

Power Supply (V/Ph/Hz)

220-240/1/60

Rated Current (Amp)

10.2

Maximum Current (Amp)

14.81

Refrigerant Type

R410A

Compressor

Panasonic

Condenser Fan Quantity

1

Condenser Fan Airflow

3000

m³/hr

1765

ft³/min

Condenser Fan Rated Power

100

Watt

100

Watt

Fluid Side Heat Exchanger Type

Plate Heat Exchanger

Fluid Side Pressure Drop

20

Kpa

6.692

ft of Water

Piping Connection Size

1"

Allowable Water Flow (Min / Rated / Max)

0.28/0.45/0.76

L/s

4.44/7.13/12.05

US gpm

Noise Level

59

Net Dimensions (LxDxH)

1110x475x810

mm x mm x mm

44x19x32

in x in x in

Packaging Dimensions (LxDxH)

1220x540x970

mm x mm x mm

48x22x39

in x in x in

Net Weight

88

Kg

194

Lb

Gross Weight

116

Kg

256

Lb

Notes

 

 

 

 

DB: Outdoor Dry Bulb Temperature

WB: Outdoor Wet Bulb Temperature

COP: Coefficient of Performance = Heat Output in KW / Power Input in KW

EER: Energy Efficiency Ratio = Heat Output in MBH (1000 x Btu/hr) / Power Input in KW



HEATING PERFORMANCE

HSS030V2 

Outdoor Air DB Temperature (°C)

Outdoor Air DB Temperature (°F)

Supply Water Temperature 95°F (35°C) / Return Water Temperature 86°F (30°C)

Supply Water Temperature 113°F (45°C) / Return Water Temperature 104°F (40°C)

Supply Water Temperature 131°F (55°C) / Return Water Temperature 122°F (50°C)

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

Heating Capacity (KW)

Heating Capacity (BTU/HR)

Power in (KW)

COP

 -20 

-4

 4.39 

14,978

1.77

 2.48 

 3.72 

12,692

1.99

 1.87 

 1.12 

3,822

0.83

 1.35 

 -15 

5

 5.85 

19,960

2.00

 2.92 

 4.96 

16,923

2.33

 2.13 

 2.97 

10,134

1.94

 1.53 

 -7 

19.4

 7.19 

24,531

2.09

 3.44 

 6.98 

23,815

2.39

 2.92 

 6.35 

21,665

3.02

 2.10 

 2 

35.6

 8.46 

28,864

2.26

 3.74 

 8.22 

28,045

2.48

 3.32 

 7.97 

27,193

2.93

 2.72 

 7 

44.6

 9.50 

32,413

2.13

 4.45 

 8.93 

30,468

2.48

 3.60 

 8.48 

28,933

2.86

 2.96 

 12 

53.6

 9.98 

34,050

2.06

 4.85 

 9.38 

32,003

2.35

 4.00 

 8.91 

30,400

2.72

 3.28 

 20 

68

 10.47 

35,722

1.93

 5.43 

 9.85 

33,607

2.14

 4.60 

 9.35 

31,901

2.48

 3.77 

 

Technical Documents

PDF Technical Manual